Trouble shooting | Cautions |
Before asking for service, check the following ¿UVW
Phenomenon | Cause or check points | |
The system | y When unit is stopped, it won’t restart | |
does not restart | immediately until 3 minutes have elapsed | |
immediately. | to protect the system. | |
| y When the electric plug is pulled out | |
| and reinserted, the protection circuit | |
| will work for 3 minutes to protect the air | |
| conditioner. | |
| y During unit operation or at stop, a | |
Noise is heard | swishing or gurgling noise may be heard. | |
$W¿UVWPLQXWHVDIWHUXQLWVWDUWWKLV | ||
| noise is more noticeable. (This noise is | |
| JHQHUDWHGE\UHIULJHUDQWÀRZLQJLQWKH | |
| system.) | |
| y During unit operation, a cracking noise | |
Normal | may be heard. This noise is generated | |
by the casing expanding or shrinking | ||
Performance | ||
because of temperature changes. | ||
inspection | ||
y 6KRXOGWKHUHEHDELJQRLVHIURPDLUÀRZ | ||
| ||
| LQXQLWRSHUDWLRQDLU¿OWHUPD\EHWRRGLUW\ | |
Smells are | y This is because the system circulates | |
smells from the interior air such as the | ||
generated. | ||
smell of furniture, paint, cigarettes. | ||
| ||
Mist or steam are |
| |
blown out. | y During COOL or DRY operation, indoor | |
| unit may blow out mist. This is due to the | |
| sudden cooling of indoor air. | |
In dry mode, fan | y In DRY mode, when room temperature | |
speed can’t be | becomes lower than temp. setting +2 ºC, | |
changed. | unit will run intermittently at LOW speed | |
| regardless of FAN setting. | |
| y Is power plug inserted? | |
| y Is there a power failure? | |
| y Is fuse blownout? |
y,VWKHDLU¿OWHUGLUW\"
Normally it should be cleaned every
Poor cooling | 15 days. |
| y Are there any obstacles before inlet and |
Multiple | outlet? |
check | y Is temperature set correctly? |
| y Are there some doors or windows left |
| open? |
| y Is there any direct sunlight through the |
| window during the cooling operation? |
| (Use curtain) |
| y Are there too much heat sources or too |
| many people in the room during cooling |
| operation? |
y Do not obstruct or cover the ventilation grille of the air conditoner. Do not SXW¿QJHUVRUDQ\RWKHUWKLQJVLQWRWKHLQOHWRXWOHWDQGVZLQJORXYHU
y Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
6SHFL¿FDWLRQV
y The refrigerating circuit is
The machine is adaptive in following situation
1. Applicable ambient temperature range:
| Indoor | Maximum: D.B/W.B | 32 ºC/23 ºC | ||
Cooling | Minimum: D.B/W.B | 21 | ºC/15 ºC | ||
| |||||
Outdoor | Maximum: D.B/W.B | 43 | ºC/26 ºC | ||
| |||||
| Minimum: D.B | 18 | ºC | ||
|
| ||||
| Indoor | Maximum: D.B | 27 | ºC | |
| Minimum: D.B | 0 ºC | |||
|
| ||||
Heating | Outdoor | Maximum: D.B/W.B | 24 | ºC/18 ºC | |
Minimum: D.B/W.B | |||||
|
| ||||
| Outdoor | Maximum: D.B/W.B | 24 | ºC/18 ºC | |
| (INVERTER) | Minimum: D.B |
2.If the power supply cord is damaged, it must be replaced by the
PDQXIDFWXUHURULWVVHUYLFHDJHQWRUDVLPLODUTXDOL¿HGSHUVRQ
3.If the fuse of indoor unit on PC board is broken, please change it with the type of T.3.15A/ 250V. If the fuse of outdoor unit is broken, change it with the type of T.25A/250V
4.The wiring method should be in line with the local wiring standard.
5.After installation, the power plug should be easily reached.
6.The waste battery should be disposed properly.
7KHDSSOLDQFHLVQRWLQWHQGHGIRUXVHE\\RXQJFKLOGUHQRULQ¿UPSHUVRQV without supervision.
8.Young children should be supervised to ensure that they do not play with the appliance.
3OHDVHHPSOR\WKHSURSHUSRZHUSOXJZKLFK¿WLQWRWKHSRZHUVXSSO\
cord.
$EUHDNHUVKRXOGEHLQFRUSRUDWHGLQWR¿[HGZLULQJ7KHEUHDNHUVKRXOG be
11.The power plug and connecting cable must have acquired the local attestation.
,QRUGHUWRSURWHFWWKHXQLWVSOHDVHWXUQRIIWKH$&¿UVWDQGDWOHDVW 30 seconds later, cutting off the power.
3OHDVHGRQ¶WLQVHUWDQ\VHQVRURQZD\VWRSYDOYHSLSH¿WWLQJ
English
EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS
CE
All the products are in conformity with the following
European provision:
-Low Voltage Directive 73/23/EEC
-Low Voltage Directive 2006/95/EC
-Electomagnetic Compatibility 89/336/EEC
-Electomagnetic Compatibility 2004/108/EC
ROHS
7KHSURGXFWVDUHIXO¿OOHGZLWKWKHUHTXLUHPHQWVLQWKHGLUHFWLYH((& of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment
(EU RoHS Directive)
WEEE
In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed
with unsorted household waste. Do not try to dismantle the
system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other part must be done by a
TXDOL¿HGLQVWDOOHULQDFFRUGDQFHZLWKUHOHYDQWORFDODQGQDWLRQDOOHJLVODWLRQ Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.
11