| Programming Sheets |
|
|
EN 104
Zones
Location | 267 to 378 |
| Refer to page 58 | |||||
Zone 1 | Locations 267 to 273 | |||||||
Default | 2 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 2 | Locations 274 to 280 | |||||||
Default | 1 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 3 | Locations 281 to 287 | |||||||
Default | 1 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 4 | Locations 288 to 294 | |||||||
Default | 1 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 5 | Locations 295 to 301 | |||||||
Default | 0 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 6 | Locations 302 to 308 | |||||||
Default | 0 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 7 | Locations 309 to 315 | |||||||
Default | 0 | 0 | 0 | 1 | 12 | 1 | 1 | |
Zone 8 | Locations 316 to 322 | |||||||
Default | 9 | 0 | 0 | 1 | 12 | 1 | 1 | |
Zone 9 | Locations 323 to 329 | |||||||
Default | 15 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 10 | Locations | 330 to 336 | ||||||
Default | 15 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 11 | Locations 337 to 343 | |||||||
Default | 15 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 12 | Locations 344 to 350 | |||||||
Default | 15 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 13 | Locations 351 to 357 | |||||||
Default | 15 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 14 | Locations 358 to 364 | |||||||
Default | 15 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 15 | Locations | 365 to 371 | ||||||
Default | 15 | 0 | 0 | 1 | 14 | 1 | 1 | |
Zone 16 | Locations 372 to 378 | |||||||
Default | 15 | 0 | 0 | 1 | 14 | 1 | 1 |
Each zone contains seven locations. The first three locations determine how the zone operates:
Zone Type | Zone Pulse | Zone Pulse |
| Count | Count Time |
|
|
|
The next two locations contain zone options:
Zone Options 1 | Zone Options 2 |
|
|
The last two locations contain reporting information:
Report Code | Dialer Options |
|
|
Zone Types
These are the zone types available:
Zone Type | Description |
0 | Instant |
1 | Handover |
2 | |
3 | |
4 | Reserved |
5 | Reserved |
6 | |
7 | |
8 | |
9 | |
10 | Reserved |
11 | Keyswitch |
12 | |
13 | |
14 | Chime only |
15 | Zone not used |
Zone Pulse Count Settings
Program the pulse count settings for each zone from 0 to 15.
Zone Pulse Count Time
Zone pulse count time is the time frame or period over which the number of pulses must register.
20 ms Loop Response | 150 ms Loop Response | ||
Option | Time (sec) | Option | Time (sec) |
0 | 0.5 | 8 | 20 |
1 | 1 | 9 | 30 |
2 | 2 | 10 | 40 |
3 | 3 | 11 | 50 |
4 | 4 | 12 | 60 |
5 | 5 | 13 | 90 |
6 | 10 | 14 | 120 |
7 | 15 | 15 | 200 |
|
|
|
|
Zone Options 1
Option | Description |
1 | Lockout siren/lockout dialer |
2 | Delay alarm reporting |
4 | Silent alarm |
8 | Sensor watch |
Zone Options 2 | |
|
|
Option | Description |
1 | Isolated in STAY Mode 1 |
2 | Zone isolation allowed |
4 | Forced arming allowed |
8 | Enable Zone Restore Report |
|
|