Bosch Appliances ICP-CC488 manual Indications from Remote Radio Transmitter Operations

Page 21

ICP-CC488 Installation Guide 4.0 Remote Radio Transmitter Operations

EN 21

Before a hand-held radio transmitter can operate the control panel, you must teach the transmitter’s radio code to the control panel. Refer to Section 4.3 Changing or Deleting Remote Radio User Codes for more information.

4.1Indications from Remote Radio Transmitter Operations

When using the 2-channel or 4-channel hand-held transmitter to operate the system, audible or visual indications, or both, can be provided by the horn speakers or the strobe. These indications allow you to operate the system from outside the premises with confidence. The installer can program audible and visual indication beeps by selecting Options 4 and 8 in Location 492 (refer to Section 18.1 System Options 1 on page 80). You can adjust the speaker beep volume in Location 491 (refer to Section 17.15).

Table 16: Horn Speaker Indication Beeps for Remote Operations

No of Beeps

System Status

One

System disarmed

Two

System armed in AWAY Mode

One two-tone beep

System armed in STAY Mode 1

Table 17: Strobe Indications for Remote Operations

Strobe Duration

System Status

3 sec

System disarmed

6 sec

System armed in AWAY Mode

6 sec

System armed in STAY Mode 1

4.2Remote Radio User Code Priority Levels

You can program the remote radio hand-held transmitters to operate only as User Codes 9 to 16. You can assign priority levels to each hand-held transmitter, allowing the transmitter to arm the system only, or to arm and disarm the system, for example. Refer to Section 13.3 User Code Priority for more information.

Before a hand-held radio transmitter can operate the control panel, you must teach the transmitter’s radio code to the control panel. Refer to Section 4.3 Changing or Deleting Remote Radio User Codes for more information.

4.3Changing or Deleting Remote Radio User Codes

You can use up to eight remote radio hand-held transmitters (User Codes 9 to 16) to operate the system. Before the control panel accepts a signal from a remote radio hand-held transmitter, the control panel must learn the transmitter’s code.

You can substitute the Installer Code for the Master Code below to change or delete remote radio User Codes.

To add or change a remote radio User Code:

1.Enter the Master Code and press [1][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the user number (9 to 16) you want to add or change and press [AWAY].

Two beeps sound and the corresponding zone indicators light. Refer to Table 18 on page 21.

Table 18: Codepad Indicators for Remote Radio User Numbers

Data

 

 

Zone Indicators

 

 

 

Value

1

2

3

4

5

6

7

8

MAINS

9

X

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

X

11

X

 

 

 

 

 

 

 

X

12

 

X

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

13

 

 

X

 

 

 

 

 

X

14

 

 

 

X

 

 

 

 

X

15

 

 

 

 

X

 

 

 

X

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

X

 

 

X

3.Enter the nine-digit RF ID number located on the back of the hand-held transmitter and press [AWAY].

Two beeps sound and the STAY and AWAY indicators are extinguished.

4.Repeat Steps 1 to 3 to add or change another remote radio User Code.

This function is automatically terminated if you do not press a button within 60 sec or if you press [AWAY].

One long beep indicates that the code already exists or you selected an incorrect user number.

When using a partitioned ICP-CC488 Control Panel, you must allocate the remote radio User Codes to one or more areas (refer to Section 19.5 User Code Allocations).

Bosch Security Systems, Inc. 12/08 F01U089457-02

Image 21
Contents ICP-CC488 Installation GuideICP-CC488 Installation Guide Notices Copyright NoticeBosch Security Systems, Inc /08 F01U089457-02 Contents 15.4 Zone Status Trouble Reports 15.5 ICP-CC488 Installation Guide Contents Tables FiguresUser Code Allocations Hexadecimal Values for Zone Nos ICP-CC488 Features ICP-CC488 Installation Guide IntroductionIntroduction Zone Defaults for the ICP-CC488 ICP-CC488 Zone DefaultsQuick Start Set the Date and TimeCodepad Indicators ICP-CC488 Installation Guide Codepad IndicatorsICP-CP508W Eight Zone LED Codepad Fault indicator Mains IndicatorAudible Indicators ICP-CP508LW Eight Zone LCD CodepadICP-CP500PW Master Partitioned LED Codepad ICP-CP516 Sixteen Zone Codepads Disarming the System from Away Mode Arming the System in Away ModeArming the System in Stay Mode ICP-CC488 Installation Guide System OperationsDisarming the System from Stay Mode Codepad Panic Alarm Codepad Duress AlarmCodepad Medical Alarm Codepad Fire AlarmIsolating Zones Standard IsolatingFault Descriptions Fault Analysis ModeAC Mains Failure System Fault indicatorsRemote Radio Transmitter Operations Fault Analysis ConditionsIndications from Remote Radio Transmitter Operations Remote Radio User Code Priority LevelsChanging or Deleting Remote Radio User Codes ICP-CC488 Installation Guide System Functions Installer Code FunctionsInstaller Code Functions Add or Delete RF Wireless DevicesSet the Number of Days until the First Test Report Change Domestic Phone NumbersDomestic Dialing Digits Examples provided for this feature apply only to Australia Codepad Indicators When Changing Phone NumbersChange Telco Arm/Disarm Sequence Telco Arm SequenceSetting Stay Mode 2 Zones Satellite Siren Service ModeTurning Telephone Monitor Mode On and Off Event Memory Recall Mode Telephone Monitor Mode IndicationsEvent Sequence Event Memory PlaybackMaster Code Functions Master Code FunctionsArm or Disarm Both Areas at the Same Time Changing and Deleting User CodesUser Numbers Displayed by the Codepad Indicators Changing and Deleting Remote Radio User CodesChanging Domestic Phone Numbers Codepad Indicators When Changing Domestic Telephone Numbers Turning Outputs On/Off When you program a # in the telco arm sequence, enter STAY2Event Non-volatile Memory Recall Mode Setting the Date and TimeArm the System in Stay Mode Arm the System in Away ModeUser Code Functions Hold-Down FunctionsFault Analysis Mode Turning Day Alarm On and OffReset Latching Outputs Horn Speaker TestRemote Arming by Telephone ICP-CC488 Installation Guide Remote Arming by TelephoneProgramming Programming with the Remote CodepadICP-CC488 Installation Guide Programming Codepad IndicatorsProgramming with the Programming Key Installer’s Programming Mode Commands Installer’s Programming CommandsCommand 959 Test the Programming Key Programming Option BitsCommand 963 Copy the Programming Key to the Control Panel Command 960 Exit from Installers Programming ModeCommand 965 Set Up Domestic Dialing Format Command 964 Erase the Programming KeyExample Auto Step Enabled Disable Factory DefaultsExample Auto Step Disabled Command 965 DefaultsICP-CC488 Installation Guide Alarm Link Software Alarm Link SoftwareRemote Connect Remote Connection with Customer ControlAlarm Link Options Enable Alarm Link Call Back ICP-CC488 Installation Guide Domestic DialingTerminate Alarm Link Connection on Alarm Domestic DialingICP-CC488 Installation Guide Dialer Reporting Formats Setting Up and Programming Domestic ReportingDialer Reporting Formats Transmission FormatsPoint ID Codes Contact ID Format Breakdown10.1.4 4 + 2 Reporting Format Example Reporting in 4 + 2 Format + 2 Reporting FormatBasic Pager Reporting Format + 2 Transmission Code Descriptions14.3.2 Basic Pager Display ICP-CC488 Installation Guide Dialer Information Dialer InformationBasic Pager Display Information Secondary Telephone Number for Receiver 1 and Receiver Primary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Dialing DigitsSubscriber ID Number for Receiver 1 and Receiver Transmission Format for Receiver 1 and ReceiverDialing Format Telco Arming SequenceCall Back Telephone Number Telco Disarming SequenceRing Count Answering Machine BypassICP-CC488 Installation Guide Dialer Options Telephone Line Fault OptionsDialer Options Dialer OptionsUse Bell 103 for FSK Format Disabled=CCITT V21 Answering Machine Bypass Only When ArmedOpen/Close Reports Only if Previous Alarm Open/Close Reports for Stay Mode 1 and Stay ModeInstaller Code Access CodesICP-CC488 Installation Guide Access Codes User CodesPriority Levels User Code PriorityArm/Disarm Arm OnlyICP-CC488 Installation Guide Zone Information Day Alarm InformationZone Information EOL Resistor ValueTamper Zone 1 3K3 Zone 5 6K8 Zone Operating Information Zone ProgrammingZone Options Zone Reporting InformationYou can program Zones 1 to 16 as any zone type Delay-2 Zone Delay-1 ZoneKeyswitch Zone Instant ZoneChime Zone 13 24-Hour Fire ZoneZone Not Used Zone Pulse CountSilent Alarm Delay Alarm ReportingKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Disarm from Stay Mode 1 or Stay Mode Latching Arm in Stay ModeMomentary Arm and Disarm in Away Mode Momentary Arm in Away ModeSwinger Shutdown Count for Dialer Swinger Shutdown Count for SirenZone Status Zone Tamper Report System Reporting InformationZone Status Walk Test Report Zone Status Bypass ReportsRF Low Battery Report Zone Status Alarm Restore CodeZone Status Sensor Watch Reports Zone Status Reporting OptionsRF Dialer Options RF Receiver Trouble Restore ReportOpen/Close Reports Open/Close Reporting OptionsSystem Status AUX Power Supply Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AC Fail Restore Report Codepad Fire ReportSystem Status Low Battery Restore Report System Status Low Battery ReportSystem Status Access Denied System Status Reporting OptionsICP-CC488 Installation Guide Programmable Outputs Programmable OutputsTest Reporting Dialer Options Output Event Types Redirecting Outputs to the Codepad BuzzerExit Warning + Entry Warning + Day Alarm Resetting Entry Warning + Day Alarm ResettingDay Alarm Enabled AUX Power Supply FailCodepad Medical Alarm Sensor Watch AlarmCodepad Fire Alarm Codepad Panic AlarmRemote Control Fire Alarm VerificationRadio Control Output 1 Not in Away Mode Radio Control Output 2 Not in Away ModeMimic Zone Area 1 in Alarm Area 2 in AlarmGlobal Chime Zone Not SealedOutput Polarity ICP-CC488 Installation Guide System Event Timers System Event TimersOutput Timing Pulsing PolaritiesEntry Timer Programming Entry/Exit TimersExit Timer Entry Guard Timer for Stay ModeCodepad Lockout Time Auto Arming Pre-Alert TimerSiren Run Time Siren Sound RateSystem and Consumer Options Access Denied Code Retries To Be Silent Assign Button 4 To Operate Stay ModeStrobe Indications for Radio Arm/Disarm Codepad Panic To Be SilentConsumer Options Radio Input Options ICP-CC488 Installation Guide Partitioning Using Codepads in a Partitioned SystemPartitioning 19.1 CP500 Master Partitioned LED CodepadZone Allocations User Code Allocations Setting Up and Programming Codepads for PartitioningZone Allocations for Areas 1 Detailed ExampleSetting Up an Area 1 Codepad Setting Up an Area 1 Codepad as the Main CodepadSetting Up an Area 2 Codepad Codepad Connections For Partitioning ExamplesICP-CC488 Installation Guide RF Information RF InformationRF Option Bit Default RF Device Mapping Devices 9 to Default RF Device Mapping Devices 1 toUsing Hexadecimal Values for RF Device Mapping Enable RF Jamming MonitorRF Device Signal Strength Devices 9 to 16 Read Only RF Device Signal Strength Devices 1 to 8 Read OnlyICP-CC488 Installation Guide Optional Equipment Optional Equipment21.3 SS914 Edmsat Satellite Siren 21.5 CC816 Alarm Link Software21.4 CC891 Programming Key ICP-CP500AW Eight Zone Area Addressable CodepadICP-CC488 Installation Guide Terminals and Descriptions Terminals and DescriptionsTerminal Descriptions Glossary Of Terms That an alarm was sent out Domestic alarm reportsStay Mode This mode. Only the installer can program these zonesICP-CC488 Wiring Diagram DiagramsICP-CC488 Installation Guide Terminals and Descriptions Telecom Connection Diagram for Australia Wiring and Power Up OperationYellow wire Green wire ICP-CC488 Installation Guide Appendices Appendix B Test Reports Only When ArmedAppendices Appendix a Telephone Anti JammingWarranty Statement SpecificationsSpecifications Software Version NumberProgramming Sheets ICP-CC488 Installation Guide Programming SheetsTick ICP-CC488 Programming SheetsAlarm Link Options Telephone Line Fault OptionsDialing Format ReservedDay Alarm Zones Installer CodeUser Code Priority Levels EOL Resistor ValueZones Zone Pulse Count SettingsRF Receiver Trouble Restore Report RF Low Battery ReportZone Descriptions Swinger Shutdown Count for SirenSystem Status AUX Power Supply Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AC Fail Restore Report System Status Low Battery ReportDelay Alarm Reporting Time Entry Guard Time for Stay ModeSpeaker Beep Volume Sensor Watch TimeRadio Input Options Zone Allocations Enabled for Area 1 and AreaZone Allocations for Area 1 and Area Domestic Telephone NumbersRF Device Signal Strength Devices 9 to RF Device Signal Strength Devices 1 toRF Options RF Device Mapping OptionCountry Codes Disable Factory DefaultSystem Time System DateICP-CC488 Installation Guide Programming Sheets ICP-CC488 Installation Guide Index Remote Connect Without Call Back Verification41 IndexTelephone Line Fault Options 52, 80 Disarming ICP-CC488 Installation Guide Index Enable User Code + 0 + Away To Arm/Disarm Zone Restore Code Bosch Security Systems, Inc. F01U089457-02