| System Functions |
|
|
EN 32
The alarm memory plays back in this order:
Table 33: Event Memory Playback
Sequence | Indication | Event |
1 | All indicators off | System disarmed |
| except MAINS |
|
2 | Zone 4 and AWAY | Alarm in Zone 4 |
| indicators light |
|
3 | Zone 3 and AWAY | Alarm in Zone 3 |
| indicators light |
|
4 | AWAY indicator | System armed in |
| lights | AWAY Mode |
Each event is indicated by a beep and a lit indicator. Resetting a disarmed
After the last event, three beeps sound to indicate the end of playback. You can stop the replay at any time by pressing [AWAY].
If the system is armed in STAY Mode 1 or STAY Mode 2, the STAY indicator shows the event memory playback. There is no differentiation between STAY Mode 1 and STAY Mode 2.
If the control panel is powered down, the memory of all events is saved.
If an
5.3User Code Functions
5.3.1Arm or Disarm Both Areas at the Same Time
This User Code function operates only with partitioned
This feature allows a user to arm or disarm the system by pressing one extra button rather than entering a code twice. You can use either the CP5 Area Addressable Codepad
To arm or disarm both areas at the same time:
Enter your User Code and press [0][AWAY]. Two beeps sound and both areas are armed or disarmed from AWAY Mode.
5.4Hold-Down Functions
5.4.1Arm the System in AWAY Mode
Holding down [#] until two beeps sound arms the system in AWAY Mode. This
This hold down function does not work if you are using an
If you are using an
5.4.2Arm the System in STAY Mode 1
Holding down [*] until two beeps sound arms the system in STAY Mode 1. This
If there was no alarm during the armed cycle, holding down [*] a sec time disarms the system from STAY Mode 1. To enable single button disarming from STAY Mode 1 using this
If an alarm occurred or entry warning was activated, a valid User Code is required to disarm the system.
Refer to Section 14.3.7 Zone Options 2 on page 63 for information on programming each zone to be automatically isolated in STAY Mode 1.
This
If you are using an
5.4.3Arm the System in STAY Mode 2
Holding down [0] until two beeps sound arms the system in STAY Mode 2. This
If no alarm occurred during the armed cycle, holding down [0] a sec time disarms the system from STAY Mode 2. To enable single button disarming from STAY Mode 2 using this