| RF Information |
|
|
EN 88
Figure 21: Connections for CP-5 Master Partitioned Codepad and CP-5 Area Addressable Codepad
1 | – Data | 5 | – Master Partitioned |
2 | – CLK |
| Codepad |
3 | – +12 V | 6 | – Addressable Area |
4 | – GND |
| Codepad |
|
|
Set the DIP Switches and program these locations for the two
1.Set DIP Switch 1 on the back of the remote codepad for Area 1 to the ON position (refer to Figure 20 on page 87).
2.Set DIP Switch 2 on the back of the remote codepad for Area 2 to the ON position.
3.Select Option 2 in Location 500 (refer to Section 19.3.1 Partitioning Options 1 on page 85).
4.For Output 1, program Location 436 to 6 and Location 437 to 1 (refer to page 75).
Figure 22: Connections for Two CP-5 Area Addressable Codepads
1 – | Data | 4 – | GND |
2 – | CLK | 5 – Area 1 Codepad | |
3 – | +12 V | 6 – | Area 2 Codepad |
|
|
|
|
20.0RF Information
20.1RF Option Bit
Location 599
Default 0
1Sound siren on RF receiver fail
2Sound siren on RF receiver tamper/jamming
4Unseal zone that fails supervision (if supervision enabled)
8Enable RF jamming monitoring
1 – Sound Siren on RF Receiver Fail
If this option is selected, the horn speaker, piezo, and strobe operate when the RF receiver fails to communicate with the control panel.
2 – Sound Siren on RF Tamper/Jamming
If this option is selected, the horn speaker, piezo, and strobe operate when the tamper switch on the receiver becomes open circuit or the receiver picks up jamming signals from an RF device.
4 – Unseal Zone that Fails Supervision
If a wireless zone device fails to send a signal within the RF Supervision Time programmed in Location 393 (refer to Section 15.8) the codepad zone indicator lights as unsealed.