| System Event Timers |
|
|
EN 78
17.1Programming Entry/Exit Timers
There are two programming locations for Entry Timer 1, Entry Timer 2, Exit Time for AWAY Mode, and Entry Guard Time for STAY Mode.
The first location of the timer allows you to set the timer in increments of 1 sec. The sec location allows you to set the timer in increments of 16 sec. Add these two locations together for the total time.
Example
To set the Entry Time to 18 sec, program Location 466 as 2 (2 x 1 sec = 2 sec) and Location 467 as 1 (1 x 16 sec = 16 sec) for a total time of 18 sec (2 + 16 = 18).
17.2Entry Timer 1
Location 466 to 467
|
| Location | Default |
Increments of | 1 sec | 466 | 4 |
(0 sec to 15 sec) |
|
| |
Increments of | 16 sec | 467 | 1 |
(0 sec to 240 sec) |
|
|
You can program Entry Timer 1 from 0 to 255 sec in increments of 1 sec. Entry Timer 1 is the delay time used by the
17.3Entry Timer 2
Location 468 to 467
|
| Location | Default |
Increments of | 1 sec | 468 | 8 |
(0 sec to 15 sec) |
|
| |
Increments of | 16 sec | 467 | 2 |
(0 sec to 240 sec) |
|
|
You can program Entry Timer 2 from 0 to 255 sec in increments of 1 sec. Entry Timer 2 is the delay time used by
17.4Exit Timer
Location 470 to 471
|
| Location | Default |
Increments of | 1 sec | 470 | 12 |
(0 sec to 15 sec) |
|
| |
Increments of | 16 sec | 471 | 3 |
(0 sec to 240 sec) |
|
|
You can program the Exit Timer from 0 to 255 sec in increments of 1 sec. When arming the system in AWAY Mode, the remote codepad beeps during Exit Time until the final 10 sec, when the codepad sounds one continuous beep to indicate the end of Exit Time is near.
The remote codepad always sounds one short beep at the end of Exit Time when arming in STAY Mode 1 or STAY Mode 2.
17.5Entry Guard Timer for STAY Mode
Location 472 to 473
|
| Location | Default |
Increments of | 1 sec | 472 | 0 |
(0 sec to 15 sec) |
|
| |
Increments of | 16 sec | 473 | 0 |
(0 sec to 240 sec) |
|
|
Entry Guard Timer for STAY Mode is the delay time used for all zones except
Refer to Section 14.3.7 to program zones to be automatically isolated in STAY Mode 1. Refer to Section 5.2.6 to program zones to be automatically isolated in STAY Mode 2.
17.6Delay Alarm Reporting Time
Location 474 to 475
| Location | Default |
Increments of 1 sec (0 sec to | 474 | 0 |
15 sec) |
|
|
Increments of 16 sec (0 sec to | 475 | 0 |
240 sec) |
|
|
These locations program the time in sec that a delayed report waits dormant in the dial buffer before it is sent to the receiving party. If a User Code holder resets the alarm within this time frame, the control panel clears the dialer buffer and does not report the alarm to the receiving party. Refer to Section 14.3.5 Zone Options 1 on page 61 to program zones for delay alarm reporting.
17.7Sensor Watch Time
Location 476 to 477
| Location | Default |
Increments of days (tens digit) | 476 | 0 |
Increments of days (units digit) | 477 | 0 |
The time set in these two locations determines the number of days (0 to 99) a zone can remain sealed before registering as a fault. This feature is active only when the system is disarmed. If a zone programmed for Sensor Watch is not unsealed and reset during this time, the FAULT indicator lights. Refer to Section 3.13 Fault Descriptions on page 18 for more information on Sensor Watch Faults. Refer to Section 14.3.5 Zone Options 1 on page 61 for programming zones for Sensor Watch.