Bosch Appliances ICP-CC488 manual Alarm Link Options

Page 41

ICP-CC488 Installation Guide 8.0

Alarm Link Software

 

 

EN 41

Program the Call Back Telephone Number in Locations 159 to 174 (refer to Section 11.9 on page 51).

Disable Option 1 in Location 180 (refer to Section 8.2 Alarm Link Options on page 41).

The control panel is set so the client controls when a remote connection is established.

To dial the remote computer:

Press and hold [6] until two beeps sound on the remote codepad.

8.1.2Remote Connection without Callback Verification

Remote connect without callback verification is useful if you must perform Upload/Download functions from multiple locations.

There are two methods to disable callback verification. Using this feature reduces the security of the control panel.

Method One

Method one allows you to call the control panel from any remote location without the control panel calling back to the computer to establish a link. When using this method, the customer cannot initiate a modem call by holding down [6].

To program method one:

1.Program Locations 159 to 174 for the Call Back Telephone Number to 0 (refer to Section 11.9 on page 51).

2.Select Option 1 and disable Option 2 in Location 180 (refer to Section 8.2 Alarm Link Options on page 41).

The control panel allows a connection of the first call without calling the remote computer back.

Method Two

Method two allows you to program a callback telephone number so that the customer can still initiate a modem call when required. When you call the control panel from a remote location using the computer, the control panel does not call back the remote computer to establish a link.

To program method two:

1.Program the Call Back Telephone Number in Locations 159 to 174 (refer to Section 11.9 on page 51).

2.Select Option 1 and disable Option 2 in Location 180 (refer to Section 8.2 Alarm Link Options on page 41).

The control panel allows a connection of the first call without calling back the remote computer to make contact. It allows the customer to initiate a modem call by holding down [6].

8.1.3Remote Connection with Callback Verification

Remote connect with callback verification offers the highest degree of data security by incorporating a two-level security check.

The first level is provided because the Installer Code and the Subscriber ID Number must match those of the control panel. The sec level of security exists because the control panel calls the programmed callback telephone number to establish the valid connection.

To program the control panel for remote connection with callback verification:

1.Program the Call Back Telephone Number in Locations 159 to 174 (refer to Section 11.9 on page 51).

2.Select Options 1 and 2 in Location 180 (refer to Section 8.2 Alarm Link Options on page 41).

8.1.4Direct Connection

The direct connect feature gives the installer a simple method to program the ICP-CC488 Control Panel using a portable computer. Because telephone lines and modems are not required, programming of the control panel is easily completed in min.

To use the direct connect feature, connect the CC808 Direct Link Cable between the correct serial port on your IBM or compatible computer and the auxiliary module socket on the control panel.

To use the direct connect feature, it is not necessary to select Option 1 Location 180. The direct connect feature ignores this option.

8.2Alarm Link Options

Location 180

1Enable upload/download using Alarm Link

2 Enable Alarm Link call back

4 Terminate Alarm Link connection on alarm

8 Reserved

When programming these locations, you can select any of four options. You can select any combination of the options by programming a single value. Calculate this value by adding the option bit numbers together. Refer to Section 7.3 Programming Option Bits on page 36 for more information.

1 – Enable Upload/Download Using Alarm Link

Select this option to use the CC816 Alarm Link Software to program the control panel remotely. The control panel does not respond to the Alarm Link Software if this option is not selected. Refer to Section

8.0Alarm Link Software on page 40 for more information.

Bosch Security Systems, Inc. 12/08 F01U089457-02

Image 41
Contents ICP-CC488 Installation GuideBosch Security Systems, Inc /08 F01U089457-02 ICP-CC488 Installation Guide NoticesCopyright Notice Contents 15.4 Zone Status Trouble Reports 15.5 ICP-CC488 Installation Guide Contents Tables FiguresUser Code Allocations Hexadecimal Values for Zone Nos Introduction ICP-CC488 FeaturesICP-CC488 Installation Guide Introduction Zone Defaults for the ICP-CC488 ICP-CC488 Zone DefaultsQuick Start Set the Date and TimeICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC488 Installation Guide Codepad Indicators Fault indicator Mains IndicatorAudible Indicators ICP-CP508LW Eight Zone LCD CodepadICP-CP500PW Master Partitioned LED Codepad ICP-CP516 Sixteen Zone Codepads Disarming the System from Away Mode Arming the System in Away ModeArming the System in Stay Mode ICP-CC488 Installation Guide System OperationsDisarming the System from Stay Mode Codepad Panic Alarm Codepad Duress AlarmCodepad Medical Alarm Codepad Fire AlarmIsolating Zones Standard IsolatingFault Descriptions Fault Analysis ModeAC Mains Failure System Fault indicatorsRemote Radio Transmitter Operations Fault Analysis ConditionsChanging or Deleting Remote Radio User Codes Indications from Remote Radio Transmitter OperationsRemote Radio User Code Priority Levels ICP-CC488 Installation Guide System Functions Installer Code FunctionsInstaller Code Functions Add or Delete RF Wireless DevicesDomestic Dialing Digits Set the Number of Days until the First Test ReportChange Domestic Phone Numbers Examples provided for this feature apply only to Australia Codepad Indicators When Changing Phone NumbersChange Telco Arm/Disarm Sequence Telco Arm SequenceTurning Telephone Monitor Mode On and Off Setting Stay Mode 2 ZonesSatellite Siren Service Mode Event Memory Recall Mode Telephone Monitor Mode IndicationsEvent Sequence Event Memory PlaybackMaster Code Functions Master Code FunctionsArm or Disarm Both Areas at the Same Time Changing and Deleting User CodesChanging Domestic Phone Numbers User Numbers Displayed by the Codepad IndicatorsChanging and Deleting Remote Radio User Codes Codepad Indicators When Changing Domestic Telephone Numbers Turning Outputs On/Off When you program a # in the telco arm sequence, enter STAY2Event Non-volatile Memory Recall Mode Setting the Date and TimeArm the System in Stay Mode Arm the System in Away ModeUser Code Functions Hold-Down FunctionsFault Analysis Mode Turning Day Alarm On and OffReset Latching Outputs Horn Speaker TestRemote Arming by Telephone ICP-CC488 Installation Guide Remote Arming by TelephoneProgramming Programming with the Remote CodepadProgramming with the Programming Key ICP-CC488 Installation Guide ProgrammingCodepad Indicators Installer’s Programming Mode Commands Installer’s Programming CommandsCommand 959 Test the Programming Key Programming Option BitsCommand 963 Copy the Programming Key to the Control Panel Command 960 Exit from Installers Programming ModeCommand 965 Set Up Domestic Dialing Format Command 964 Erase the Programming KeyExample Auto Step Enabled Disable Factory DefaultsExample Auto Step Disabled Command 965 DefaultsICP-CC488 Installation Guide Alarm Link Software Alarm Link SoftwareRemote Connect Remote Connection with Customer ControlAlarm Link Options Enable Alarm Link Call Back ICP-CC488 Installation Guide Domestic DialingTerminate Alarm Link Connection on Alarm Domestic DialingICP-CC488 Installation Guide Dialer Reporting Formats Setting Up and Programming Domestic ReportingDialer Reporting Formats Transmission FormatsPoint ID Codes Contact ID Format Breakdown10.1.4 4 + 2 Reporting Format Example Reporting in 4 + 2 Format + 2 Reporting FormatBasic Pager Reporting Format + 2 Transmission Code Descriptions14.3.2 Basic Pager Display Basic Pager Display Information ICP-CC488 Installation Guide Dialer InformationDialer Information Secondary Telephone Number for Receiver 1 and Receiver Primary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Dialing DigitsSubscriber ID Number for Receiver 1 and Receiver Transmission Format for Receiver 1 and ReceiverDialing Format Telco Arming SequenceCall Back Telephone Number Telco Disarming SequenceRing Count Answering Machine BypassICP-CC488 Installation Guide Dialer Options Telephone Line Fault OptionsDialer Options Dialer OptionsUse Bell 103 for FSK Format Disabled=CCITT V21 Answering Machine Bypass Only When ArmedOpen/Close Reports Only if Previous Alarm Open/Close Reports for Stay Mode 1 and Stay ModeInstaller Code Access CodesICP-CC488 Installation Guide Access Codes User CodesPriority Levels User Code PriorityArm/Disarm Arm OnlyICP-CC488 Installation Guide Zone Information Day Alarm InformationZone Information EOL Resistor ValueTamper Zone 1 3K3 Zone 5 6K8 Zone Operating Information Zone ProgrammingZone Options Zone Reporting InformationYou can program Zones 1 to 16 as any zone type Delay-2 Zone Delay-1 ZoneKeyswitch Zone Instant ZoneChime Zone 13 24-Hour Fire ZoneZone Not Used Zone Pulse CountSilent Alarm Delay Alarm ReportingKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Disarm from Stay Mode 1 or Stay Mode Latching Arm in Stay ModeMomentary Arm and Disarm in Away Mode Momentary Arm in Away ModeSwinger Shutdown Count for Dialer Swinger Shutdown Count for SirenZone Status Zone Tamper Report System Reporting InformationZone Status Walk Test Report Zone Status Bypass ReportsRF Low Battery Report Zone Status Alarm Restore CodeZone Status Sensor Watch Reports Zone Status Reporting OptionsRF Dialer Options RF Receiver Trouble Restore ReportOpen/Close Reports Open/Close Reporting OptionsSystem Status AUX Power Supply Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AC Fail Restore Report Codepad Fire ReportSystem Status Low Battery Restore Report System Status Low Battery ReportSystem Status Access Denied System Status Reporting OptionsTest Reporting Dialer Options ICP-CC488 Installation Guide Programmable OutputsProgrammable Outputs Output Event Types Redirecting Outputs to the Codepad BuzzerExit Warning + Entry Warning + Day Alarm Resetting Entry Warning + Day Alarm ResettingDay Alarm Enabled AUX Power Supply FailCodepad Medical Alarm Sensor Watch AlarmCodepad Fire Alarm Codepad Panic AlarmRemote Control Fire Alarm VerificationRadio Control Output 1 Not in Away Mode Radio Control Output 2 Not in Away ModeMimic Zone Area 1 in Alarm Area 2 in AlarmGlobal Chime Zone Not SealedOutput Polarity ICP-CC488 Installation Guide System Event Timers System Event TimersOutput Timing Pulsing PolaritiesEntry Timer Programming Entry/Exit TimersExit Timer Entry Guard Timer for Stay ModeCodepad Lockout Time Auto Arming Pre-Alert TimerSiren Run Time Siren Sound RateSystem and Consumer Options Access Denied Code Retries To Be Silent Assign Button 4 To Operate Stay ModeStrobe Indications for Radio Arm/Disarm Codepad Panic To Be SilentConsumer Options Radio Input Options ICP-CC488 Installation Guide Partitioning Using Codepads in a Partitioned SystemPartitioning 19.1 CP500 Master Partitioned LED CodepadZone Allocations User Code Allocations Setting Up and Programming Codepads for PartitioningZone Allocations for Areas 1 Detailed ExampleSetting Up an Area 1 Codepad Setting Up an Area 1 Codepad as the Main CodepadSetting Up an Area 2 Codepad Codepad Connections For Partitioning ExamplesRF Option Bit ICP-CC488 Installation Guide RF InformationRF Information Default RF Device Mapping Devices 9 to Default RF Device Mapping Devices 1 toUsing Hexadecimal Values for RF Device Mapping Enable RF Jamming MonitorRF Device Signal Strength Devices 9 to 16 Read Only RF Device Signal Strength Devices 1 to 8 Read OnlyICP-CC488 Installation Guide Optional Equipment Optional Equipment21.3 SS914 Edmsat Satellite Siren 21.5 CC816 Alarm Link Software21.4 CC891 Programming Key ICP-CP500AW Eight Zone Area Addressable CodepadTerminal Descriptions ICP-CC488 Installation Guide Terminals and DescriptionsTerminals and Descriptions Glossary Of Terms That an alarm was sent out Domestic alarm reportsStay Mode This mode. Only the installer can program these zonesICP-CC488 Wiring Diagram DiagramsICP-CC488 Installation Guide Terminals and Descriptions Telecom Connection Diagram for Australia Wiring and Power Up OperationYellow wire Green wire ICP-CC488 Installation Guide Appendices Appendix B Test Reports Only When ArmedAppendices Appendix a Telephone Anti JammingWarranty Statement SpecificationsSpecifications Software Version NumberProgramming Sheets ICP-CC488 Installation Guide Programming SheetsTick ICP-CC488 Programming SheetsAlarm Link Options Telephone Line Fault OptionsDialing Format ReservedDay Alarm Zones Installer CodeUser Code Priority Levels EOL Resistor ValueZones Zone Pulse Count SettingsRF Receiver Trouble Restore Report RF Low Battery ReportZone Descriptions Swinger Shutdown Count for SirenSystem Status AUX Power Supply Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AC Fail Restore Report System Status Low Battery ReportDelay Alarm Reporting Time Entry Guard Time for Stay ModeSpeaker Beep Volume Sensor Watch TimeRadio Input Options Zone Allocations Enabled for Area 1 and AreaZone Allocations for Area 1 and Area Domestic Telephone NumbersRF Device Signal Strength Devices 9 to RF Device Signal Strength Devices 1 toRF Options RF Device Mapping OptionCountry Codes Disable Factory DefaultSystem Time System DateICP-CC488 Installation Guide Programming Sheets ICP-CC488 Installation Guide Index Remote Connect Without Call Back Verification41 IndexTelephone Line Fault Options 52, 80 Disarming ICP-CC488 Installation Guide Index Enable User Code + 0 + Away To Arm/Disarm Zone Restore Code Bosch Security Systems, Inc. F01U089457-02