| System Operations |
|
|
EN 19
Table 14: System FAULT indicators
Indicator | Fault Description |
1Low battery
This fault registers when the system detects a low capacity backup battery. The system automatically performs a battery test every 4 hours and every time you arm the system.
2Date and time
This fault registers when the system is powered down. The fault does not cause the FAULT indicator to light on the codepad unless automatic arming time is programmed. To program the date and time, refer to Section 5.2.8.
3RF receiver fault
This fault registers when the RF wireless receiver unit detects RF jamming, the RF wireless receiver is disconnected from the control panel or failed, or the RF receiver’s cover tamper switch is activated.
4Horn speaker
This fault registers when the system detects the horn speaker is disconnected. This fault clears when the horn speaker is reconnected. This feature is enabled by selecting Option 2 in Location 492 (refer to Section 18.1 System Options 1).
5Telephone line fault
This fault registers when the system detects the telephone line is disconnected from the control panel. This feature is enabled by selecting Option 1 in Location 176 (refer to Section 11.11 Telephone Line Fault Options).
6EEPROM fail
This fault registers when the system detects an internal checksum error. Contact your installer if this fault is displayed.
7AUX Power Supply fail
This fault occurs when the AUX Power Supply has failed. Contact your installer when this fault occurs.
AC MAINS Failure
An AC MAINS supply failure automatically flashes the MAINS indicator. If the AC MAINS supply is disconnected continuously for longer than 2 min, the remote codepad beeps the codepad buzzer once per min. If the control panel is programmed to report an AC MAINS failure to a base station receiver, an AC Fail Report (Contact ID Event Code 301) is transmitted.
The MAINS indicator stops flashing when the AC MAINS supply is reconnected. When the AC MAINS supply is connected continuously for 2 min, the codepad stops the once per min beep and an AC Fail Restore Report is transmitted to the base station receiver.
If the Enable AC Fail in 1 Hour option (1) is selected in Location 494 (refer to Section 18.3 System Options 3 on page 81), the codepad flashes the MAINS indicator when the AC MAINS supply is disconnected, but does not activate the dialer or the codepad buzzer unless the AC MAINS supply is disconnected continuously for 1 hour.
If the Ignore AC MAINS Fail option (2) is selected in Location 494 (refer to Section 18.3 System Options 3 on page 81 the codepad does not indicate when the AC MAINS supply fails, but the control panel still reports an AC Fail Report, if enabled.