Bosch Appliances ICP-CC488 manual System and Consumer Options

Page 80

ICP-CC488 Installation Guide 18.0

System and Consumer Options

 

 

EN 80

For partitioned ICP-CC488 Control Panels, both areas are automatically disarmed at the same time each day.

17.14 Kiss-Off Wait Time

Location 490

Default 3

Increments of 500 ms (500 ms to 8 sec)

This location sets the time the control panel waits for acknowledgment before resending a report. This timer applies only to the 4 + 2 Express Format.

17.15 Speaker Beep Volume

Location 491

Default 13

0No beeps

15 Loudest beeps

This location allows you to adjust the speaker volume for remote radio operation.

17.16 System Time

Location 901 to 904

 

Location

Default

Hour of the day (tens digit)

901

0

Hour of the day (units digit)

902

0

Minute of the day (tens digit)

903

0

Minute of the day (units digit)

904

0

The ICP-CC488 Control Panel has a real-time 24- hour clock you must set during installation. Set this time in 24-hour HHMM format (for example, program 10:30 PM as 2230). You must reset the System Time every time the system is powered down.

17.17 System Date

Location 905 to 910

 

Location

Default

Day of the month (tens digit)

905

0

Day of the month (units digit)

906

1

Month of the year (tens digit)

907

0

Month of the year (units digit)

908

1

Current year (tens digit)

909

0

Current year (units digit)

910

1

The ICP-CC488 Control Panel has a real-time

12-month calendar you must set during installation. Set the date in DDMMYY format (for example, program 1 January 2004 as 010104). You must reset the System Date every time the system is powered down.

To set the date and time:

1.Enter your Master Code and press [6][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the day, month, year, hour, and minute in DD, MM, YY, HH, MM format (where DD is the day of the month, MM is the month of the year, YY is the year, HH is the hour of the day, and MM minute of the day) and press [AWAY]. Use 24:00 hour format when programming the hour of the day.

Two beeps sound and the STAY and AWAY indicators are extinguished. If a long beep sounds, there was an error when you entered the date and time.

Example

To set the date and time for the 1st January 2004 at 10:30 PM, enter:

[2 5 8 0 6][AWAY][0 1 0 1 0 4 2 2 3 0][AWAY]

18.0 System and Consumer Options

The locations in this section have up to four options. You can select any combination of these options by programming a single value. Calculate this value by adding the option bit numbers together. Refer to Section 7.3 Programming Option Bits on page 36 for more information.

18.1System Options 1

Location 492

1Bosch Security Systems, Inc. smart lockout allowed

2 Horn speaker monitor

4 Strobe indications for radio arm/disarm

8Assign Button 4 on transmitter to operate STAY Mode 1

1 – Smart Lockout Allowed

This feature allows the control panel to remove any zones that are programmed for lockout dialer from the lockout list when the sirens are running. This feature allows a monitoring station to receive zone alarm reports from previously locked out zones during siren time. Refer to Section 14.3.5 Zone Options 1 on page 61 for information on programming zones for lockout dialer and lockout siren.

Refer to Section 14.5 Swinger Shutdown Count for Dialer on page 64 to program the number of times the zone can report before being locked out.

2 – Horn Speaker Monitor

If this option is selected, the control panel detects when the horn speaker is disconnected from the speaker terminals. The FAULT indicator lights when the horn speaker is disconnected and is extinguished when the horn speaker is reconnected.

If an output is required to operate when the horn speaker is disconnected, use Output Event Type 1,6 Horn Speaker Monitor Fail (refer to page 72 for more information).

Bosch Security Systems, Inc. 12/08 F01U089457-02

Image 80
Contents Installation Guide ICP-CC488Bosch Security Systems, Inc /08 F01U089457-02 ICP-CC488 Installation Guide NoticesCopyright Notice Contents 15.4 Zone Status Trouble Reports 15.5 ICP-CC488 Installation Guide Contents Figures TablesUser Code Allocations Hexadecimal Values for Zone Nos Introduction ICP-CC488 FeaturesICP-CC488 Installation Guide Introduction ICP-CC488 Zone Defaults Zone Defaults for the ICP-CC488Quick Start Set the Date and TimeICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC488 Installation Guide Codepad Indicators Mains Indicator Fault indicatorAudible Indicators ICP-CP508LW Eight Zone LCD CodepadICP-CP500PW Master Partitioned LED Codepad ICP-CP516 Sixteen Zone Codepads Arming the System in Away Mode Disarming the System from Away ModeArming the System in Stay Mode ICP-CC488 Installation Guide System OperationsDisarming the System from Stay Mode Codepad Duress Alarm Codepad Panic AlarmCodepad Fire Alarm Codepad Medical AlarmIsolating Zones Standard IsolatingFault Analysis Mode Fault DescriptionsSystem Fault indicators AC Mains FailureFault Analysis Conditions Remote Radio Transmitter OperationsChanging or Deleting Remote Radio User Codes Indications from Remote Radio Transmitter OperationsRemote Radio User Code Priority Levels Installer Code Functions ICP-CC488 Installation Guide System FunctionsInstaller Code Functions Add or Delete RF Wireless DevicesDomestic Dialing Digits Set the Number of Days until the First Test ReportChange Domestic Phone Numbers Codepad Indicators When Changing Phone Numbers Examples provided for this feature apply only to AustraliaChange Telco Arm/Disarm Sequence Telco Arm SequenceTurning Telephone Monitor Mode On and Off Setting Stay Mode 2 ZonesSatellite Siren Service Mode Telephone Monitor Mode Indications Event Memory Recall ModeEvent Sequence Event Memory PlaybackMaster Code Functions Master Code FunctionsArm or Disarm Both Areas at the Same Time Changing and Deleting User CodesChanging Domestic Phone Numbers User Numbers Displayed by the Codepad IndicatorsChanging and Deleting Remote Radio User Codes Codepad Indicators When Changing Domestic Telephone Numbers When you program a # in the telco arm sequence, enter STAY2 Turning Outputs On/OffSetting the Date and Time Event Non-volatile Memory Recall ModeArm the System in Away Mode Arm the System in Stay ModeUser Code Functions Hold-Down FunctionsTurning Day Alarm On and Off Fault Analysis ModeReset Latching Outputs Horn Speaker TestICP-CC488 Installation Guide Remote Arming by Telephone Remote Arming by TelephoneProgramming Programming with the Remote CodepadProgramming with the Programming Key ICP-CC488 Installation Guide ProgrammingCodepad Indicators Installer’s Programming Commands Installer’s Programming Mode CommandsCommand 959 Test the Programming Key Programming Option BitsCommand 960 Exit from Installers Programming Mode Command 963 Copy the Programming Key to the Control PanelCommand 964 Erase the Programming Key Command 965 Set Up Domestic Dialing FormatDisable Factory Defaults Example Auto Step EnabledExample Auto Step Disabled Command 965 DefaultsAlarm Link Software ICP-CC488 Installation Guide Alarm Link SoftwareRemote Connect Remote Connection with Customer ControlAlarm Link Options ICP-CC488 Installation Guide Domestic Dialing Enable Alarm Link Call BackTerminate Alarm Link Connection on Alarm Domestic DialingSetting Up and Programming Domestic Reporting ICP-CC488 Installation Guide Dialer Reporting FormatsDialer Reporting Formats Transmission FormatsContact ID Format Breakdown Point ID Codes10.1.4 4 + 2 Reporting Format Example Reporting in 4 + 2 Format + 2 Reporting Format+ 2 Transmission Code Descriptions Basic Pager Reporting Format14.3.2 Basic Pager Display Basic Pager Display Information ICP-CC488 Installation Guide Dialer InformationDialer Information Primary Telephone Number for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Dialing DigitsTransmission Format for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverDialing Format Telco Arming SequenceTelco Disarming Sequence Call Back Telephone NumberRing Count Answering Machine BypassTelephone Line Fault Options ICP-CC488 Installation Guide Dialer OptionsDialer Options Dialer OptionsAnswering Machine Bypass Only When Armed Use Bell 103 for FSK Format Disabled=CCITT V21Open/Close Reports Only if Previous Alarm Open/Close Reports for Stay Mode 1 and Stay ModeAccess Codes Installer CodeICP-CC488 Installation Guide Access Codes User CodesUser Code Priority Priority LevelsArm/Disarm Arm OnlyDay Alarm Information ICP-CC488 Installation Guide Zone InformationZone Information EOL Resistor ValueTamper Zone 1 3K3 Zone 5 6K8 Zone Programming Zone Operating InformationZone Options Zone Reporting InformationYou can program Zones 1 to 16 as any zone type Delay-1 Zone Delay-2 ZoneKeyswitch Zone Instant Zone13 24-Hour Fire Zone Chime ZoneZone Not Used Zone Pulse CountDelay Alarm Reporting Silent AlarmKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Arm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeMomentary Arm and Disarm in Away Mode Momentary Arm in Away ModeSwinger Shutdown Count for Siren Swinger Shutdown Count for DialerSystem Reporting Information Zone Status Zone Tamper ReportZone Status Walk Test Report Zone Status Bypass ReportsZone Status Alarm Restore Code RF Low Battery ReportZone Status Sensor Watch Reports Zone Status Reporting OptionsRF Receiver Trouble Restore Report RF Dialer OptionsOpen/Close Reports Open/Close Reporting OptionsSystem Status AUX Power Supply Fail Report System Status AUX Power Supply Fail Restore ReportSystem Status AC Fail Restore Report Codepad Fire ReportSystem Status Low Battery Report System Status Low Battery Restore ReportSystem Status Access Denied System Status Reporting OptionsTest Reporting Dialer Options ICP-CC488 Installation Guide Programmable OutputsProgrammable Outputs Redirecting Outputs to the Codepad Buzzer Output Event TypesEntry Warning + Day Alarm Resetting Exit Warning + Entry Warning + Day Alarm ResettingDay Alarm Enabled AUX Power Supply FailSensor Watch Alarm Codepad Medical AlarmCodepad Fire Alarm Codepad Panic AlarmFire Alarm Verification Remote ControlRadio Control Output 1 Not in Away Mode Radio Control Output 2 Not in Away ModeArea 1 in Alarm Area 2 in Alarm Mimic ZoneGlobal Chime Zone Not SealedOutput Polarity System Event Timers ICP-CC488 Installation Guide System Event TimersOutput Timing Pulsing PolaritiesProgramming Entry/Exit Timers Entry TimerExit Timer Entry Guard Timer for Stay ModeAuto Arming Pre-Alert Timer Codepad Lockout TimeSiren Run Time Siren Sound RateSystem and Consumer Options Assign Button 4 To Operate Stay Mode Access Denied Code Retries To Be SilentStrobe Indications for Radio Arm/Disarm Codepad Panic To Be SilentConsumer Options Radio Input Options Using Codepads in a Partitioned System ICP-CC488 Installation Guide PartitioningPartitioning 19.1 CP500 Master Partitioned LED CodepadZone Allocations Setting Up and Programming Codepads for Partitioning User Code AllocationsZone Allocations for Areas 1 Detailed ExampleSetting Up an Area 1 Codepad as the Main Codepad Setting Up an Area 1 CodepadSetting Up an Area 2 Codepad Codepad Connections For Partitioning ExamplesRF Option Bit ICP-CC488 Installation Guide RF InformationRF Information Default RF Device Mapping Devices 1 to Default RF Device Mapping Devices 9 toUsing Hexadecimal Values for RF Device Mapping Enable RF Jamming MonitorRF Device Signal Strength Devices 1 to 8 Read Only RF Device Signal Strength Devices 9 to 16 Read OnlyICP-CC488 Installation Guide Optional Equipment Optional Equipment21.5 CC816 Alarm Link Software 21.3 SS914 Edmsat Satellite Siren21.4 CC891 Programming Key ICP-CP500AW Eight Zone Area Addressable CodepadTerminal Descriptions ICP-CC488 Installation Guide Terminals and DescriptionsTerminals and Descriptions Glossary Of Terms Domestic alarm reports That an alarm was sent outStay Mode This mode. Only the installer can program these zonesDiagrams ICP-CC488 Wiring DiagramICP-CC488 Installation Guide Terminals and Descriptions Wiring and Power Up Operation Telecom Connection Diagram for AustraliaYellow wire Green wire Appendix B Test Reports Only When Armed ICP-CC488 Installation Guide AppendicesAppendices Appendix a Telephone Anti JammingSpecifications Warranty StatementSpecifications Software Version NumberICP-CC488 Installation Guide Programming Sheets Programming SheetsTick ICP-CC488 Programming SheetsTelephone Line Fault Options Alarm Link OptionsDialing Format ReservedInstaller Code Day Alarm ZonesUser Code Priority Levels EOL Resistor ValueZone Pulse Count Settings ZonesRF Low Battery Report RF Receiver Trouble Restore ReportZone Descriptions Swinger Shutdown Count for SirenSystem Status AUX Power Supply Fail Report System Status AUX Power Supply Fail Restore ReportSystem Status AC Fail Restore Report System Status Low Battery ReportEntry Guard Time for Stay Mode Delay Alarm Reporting TimeSpeaker Beep Volume Sensor Watch TimeZone Allocations Enabled for Area 1 and Area Radio Input OptionsZone Allocations for Area 1 and Area Domestic Telephone NumbersRF Device Signal Strength Devices 1 to RF Device Signal Strength Devices 9 toRF Options RF Device Mapping OptionDisable Factory Default Country CodesSystem Time System DateICP-CC488 Installation Guide Programming Sheets ICP-CC488 Installation Guide Index Index Remote Connect Without Call Back Verification41Telephone Line Fault Options 52, 80 Disarming ICP-CC488 Installation Guide Index Enable User Code + 0 + Away To Arm/Disarm Zone Restore Code Bosch Security Systems, Inc. F01U089457-02