| Specifications |
|
|
EN 100
Select Option 1 (Send Test Reports only if the system is armed) in Location 428 (refer to Section 18.5 Consumer Options 1 on page 82) and then set the Test Report Time to be in the middle of the day. During Monday to Friday when the premises are generally open and the system is disarmed, a Test Report is not sent. On the weekend, the premises are closed and the system armed, so a Test Report is sent at the programmed time to verify the operation of the dialer.
At first glance, this may not seem to be significant, but by doing a few sums you can see where savings are possible.
Assume that the customer wants, needs, or has Test Reports programmed for once per day with Opening and Closing reports. In this scenario, at least three phone calls are made each weekday, one call on Saturday, and one call on Sunday.
By using the
Not a bad saving, but remember these figures are for local calls only.
Now assume a control room with 1000 customers sending the same reports. It can expect to receive 884,000 phone calls ($221,000 assuming local calls) just for reporting Opening, Closing, and Test reports over a twelve month period.
If you use the
As you can see using the
24.0Specifications
24.1Warranty Statement
Bosch Security Systems, Inc. warrants this product to be free from defects in material and workmanship for a period of three years from the date of manufacture as indicated by the date stamp or the serial number on the product.
Defective units returned by the purchaser at their own expense during this period will be repaired or replaced at the option of the manufacturer. The repair or replacement will be free of charge provided that the defects were not incurred during shipping or handling, or the damage was not due to causes beyond the control of Bosch Security Systems, Inc., such as lightning, excessive voltage, mechanical shock, or damage arising out of abuse, alteration, or improper application of the equipment.
24.2Specifications
Table 65: Specifications
Temperature Range | 0oC to +45 oC |
| (+32 oF to +113 oF) |
Humidity | 10% to 95% |
Power Source | TF008 Plug Pack – |
| 240 V/18 VAC @ 1.3 A |
Standby Current | 65 mA |
Current Draw In | 115 mA |
Alarm Condition |
|
Current Draw In | 105 mA |
Alarm Condition With |
|
Codepad |
|
Backup Battery | 6.5 Ah/12 VDC rechargeable |
| sealed lead acid battery |
Dimensions (case, | 306 mm x 262 mm x 84 mm |
packed in carton) | (12.05 in. x 10.31 in. x 3.31 in.) |
Weight | 2.5 kg (5.51 lbs.) |
Supplier Code | N771 |
New Zealand |
|
Telepermit |
|
PTC 211/98/083 |
24.3Software Version Number
Refer to Section 7.4.9 Command 999 – Display the Panel Type or Software Version Number for more information.
24.4New Zealand Telepermit Notes
•The grant of a telepermit for a device does not indicate Telecom acceptance of responsibility for the correct operation of the device under all operating conditions.
•This equipment shall not be used in any manner that could constitute a nuisance to other Telecom customers.