System Functions

 

 

EN 25

To program the telco disarm sequence:

1.Enter the Installer Code and press [3][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Press [2][AWAY] to change the telco disarming sequence.

Three beeps sound.

If a telco disarming sequence is already programmed, the sequence is displayed one digit at a time using the remote codepad indicators. Refer to Table 21 on page 24 for the indicators and their meanings.

If no telco disarming sequence is programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the sequence is displayed.

3.Enter the desired call forward disable sequence. For example, program [# 6 1 #] to disable the call forward – no answer sequence, or [# 2 1 #] to disable the call forward – immediate sequence.

Remember that when you program a # in the telco arm sequence, you enter [STAY][2].

4.Press [AWAY].

Two beeps sound and the system returns to the disarmed state.

You can suspend the telco disarming sequence at any time.

To disable the telco disarming sequence:

Enter the Installer Code and press [3][AWAY][2] [AWAY][STAY][4][AWAY].

5.1.5Setting STAY Mode 2 Zones

This function allows the installer to select the zones that are automatically isolated when the system is armed in STAY Mode 2.

To arm the system in STAY Mode 2, press and hold

[0]until two beeps sound. Refer to Section 5.4.3 or Section 3.5 Arming The System in STAY Mode 2 for more information.

To set STAY Mode 2 zones:

1.Enter the Installer Code and press [4][AWAY]. Three beeps sound and the STAY indicator flashes.

2.Enter the number of the zone you want to automatically isolate and press [STAY]. The corresponding zone indicator flashes.

3.Repeat Step 2 for each zone you want to select.

As each zone is selected to be isolated, the corresponding zone indicator flashes. If you make a mistake, enter the incorrect zone number and press [STAY]. This zone is no longer selected to be isolated and the zone indicator is extinguished.

This function does not work on a partitioned ICP-CC488 Control Panel.

4.Press [AWAY].

Two beeps sound and the system returns to the disarmed state.

The indicators for the zones you selected and the STAY indicator are extinguished.

Example

If you want to select zones 2, 5, and 6, enter:

[1 2 3 4 4][AWAY][2][STAY][5][STAY][6][STAY] [AWAY]

You can disable all zones selected to be automatically isolated for STAY Mode 2 at any time. To disable STAY Mode 2 zones:

Enter the Installer Code and press [4][AWAY] [AWAY].

5.1.6Satellite Siren Service Mode

If the SS914 Satellite Siren (EDMSAT) is connected to Output 1, this function allows you to perform service work on the system without activating the satellite siren. The satellite siren returns to its normal working state the next time the system is armed.

To enter Satellite Siren Service Mode:

Enter the Installer Code and press [5][AWAY]. Three beeps sound.

5.1.7Turning Telephone Monitor Mode On and Off

Telephone Monitor Mode allows you to use the remote codepad for visual representation of data transmissions between the control panel and the base station receiver. The dialing sequence is also shown in this mode.

The codepad beeps once every two sec when Telephone Monitor Mode is active, whether the system is in Installer’s Programming Mode or normal operating mode. The first five indicators show the progressive steps during a transmission to the base station receiver.

After you activate Telephone Monitor Mode, hold down [9] until two beeps sound to initiate a Test Report.

Bosch Security Systems, Inc. 12/08 F01U089457-02

Image 25
Contents ICP-CC488 Installation GuideCopyright Notice ICP-CC488 Installation Guide NoticesBosch Security Systems, Inc /08 F01U089457-02 Contents 15.4 Zone Status Trouble Reports 15.5 ICP-CC488 Installation Guide Contents Tables FiguresUser Code Allocations Hexadecimal Values for Zone Nos ICP-CC488 Installation Guide Introduction ICP-CC488 FeaturesIntroduction Zone Defaults for the ICP-CC488 ICP-CC488 Zone DefaultsQuick Start Set the Date and TimeICP-CC488 Installation Guide Codepad Indicators Codepad IndicatorsICP-CP508W Eight Zone LED Codepad Fault indicator Mains IndicatorAudible Indicators ICP-CP508LW Eight Zone LCD CodepadICP-CP500PW Master Partitioned LED Codepad ICP-CP516 Sixteen Zone Codepads Disarming the System from Away Mode Arming the System in Away ModeArming the System in Stay Mode ICP-CC488 Installation Guide System OperationsDisarming the System from Stay Mode Codepad Panic Alarm Codepad Duress AlarmCodepad Medical Alarm Codepad Fire AlarmIsolating Zones Standard IsolatingFault Descriptions Fault Analysis ModeAC Mains Failure System Fault indicatorsRemote Radio Transmitter Operations Fault Analysis ConditionsRemote Radio User Code Priority Levels Indications from Remote Radio Transmitter OperationsChanging or Deleting Remote Radio User Codes ICP-CC488 Installation Guide System Functions Installer Code FunctionsInstaller Code Functions Add or Delete RF Wireless DevicesChange Domestic Phone Numbers Set the Number of Days until the First Test ReportDomestic Dialing Digits Examples provided for this feature apply only to Australia Codepad Indicators When Changing Phone NumbersChange Telco Arm/Disarm Sequence Telco Arm SequenceSatellite Siren Service Mode Setting Stay Mode 2 ZonesTurning Telephone Monitor Mode On and Off Event Memory Recall Mode Telephone Monitor Mode IndicationsEvent Sequence Event Memory PlaybackMaster Code Functions Master Code FunctionsArm or Disarm Both Areas at the Same Time Changing and Deleting User CodesChanging and Deleting Remote Radio User Codes User Numbers Displayed by the Codepad IndicatorsChanging Domestic Phone Numbers Codepad Indicators When Changing Domestic Telephone Numbers Turning Outputs On/Off When you program a # in the telco arm sequence, enter STAY2Event Non-volatile Memory Recall Mode Setting the Date and TimeArm the System in Stay Mode Arm the System in Away ModeUser Code Functions Hold-Down FunctionsFault Analysis Mode Turning Day Alarm On and OffReset Latching Outputs Horn Speaker TestRemote Arming by Telephone ICP-CC488 Installation Guide Remote Arming by TelephoneProgramming Programming with the Remote CodepadCodepad Indicators ICP-CC488 Installation Guide ProgrammingProgramming with the Programming Key Installer’s Programming Mode Commands Installer’s Programming CommandsCommand 959 Test the Programming Key Programming Option BitsCommand 963 Copy the Programming Key to the Control Panel Command 960 Exit from Installers Programming ModeCommand 965 Set Up Domestic Dialing Format Command 964 Erase the Programming KeyExample Auto Step Enabled Disable Factory DefaultsExample Auto Step Disabled Command 965 DefaultsICP-CC488 Installation Guide Alarm Link Software Alarm Link SoftwareRemote Connect Remote Connection with Customer ControlAlarm Link Options Enable Alarm Link Call Back ICP-CC488 Installation Guide Domestic DialingTerminate Alarm Link Connection on Alarm Domestic DialingICP-CC488 Installation Guide Dialer Reporting Formats Setting Up and Programming Domestic ReportingDialer Reporting Formats Transmission FormatsPoint ID Codes Contact ID Format Breakdown10.1.4 4 + 2 Reporting Format Example Reporting in 4 + 2 Format + 2 Reporting FormatBasic Pager Reporting Format + 2 Transmission Code Descriptions14.3.2 Basic Pager Display Dialer Information ICP-CC488 Installation Guide Dialer InformationBasic Pager Display Information Secondary Telephone Number for Receiver 1 and Receiver Primary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Dialing DigitsSubscriber ID Number for Receiver 1 and Receiver Transmission Format for Receiver 1 and ReceiverDialing Format Telco Arming SequenceCall Back Telephone Number Telco Disarming SequenceRing Count Answering Machine BypassICP-CC488 Installation Guide Dialer Options Telephone Line Fault OptionsDialer Options Dialer OptionsUse Bell 103 for FSK Format Disabled=CCITT V21 Answering Machine Bypass Only When ArmedOpen/Close Reports Only if Previous Alarm Open/Close Reports for Stay Mode 1 and Stay ModeInstaller Code Access CodesICP-CC488 Installation Guide Access Codes User CodesPriority Levels User Code PriorityArm/Disarm Arm OnlyICP-CC488 Installation Guide Zone Information Day Alarm InformationZone Information EOL Resistor ValueTamper Zone 1 3K3 Zone 5 6K8 Zone Operating Information Zone ProgrammingZone Options Zone Reporting InformationYou can program Zones 1 to 16 as any zone type Delay-2 Zone Delay-1 ZoneKeyswitch Zone Instant ZoneChime Zone 13 24-Hour Fire ZoneZone Not Used Zone Pulse CountSilent Alarm Delay Alarm ReportingKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Disarm from Stay Mode 1 or Stay Mode Latching Arm in Stay ModeMomentary Arm and Disarm in Away Mode Momentary Arm in Away ModeSwinger Shutdown Count for Dialer Swinger Shutdown Count for SirenZone Status Zone Tamper Report System Reporting InformationZone Status Walk Test Report Zone Status Bypass ReportsRF Low Battery Report Zone Status Alarm Restore CodeZone Status Sensor Watch Reports Zone Status Reporting OptionsRF Dialer Options RF Receiver Trouble Restore ReportOpen/Close Reports Open/Close Reporting OptionsSystem Status AUX Power Supply Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AC Fail Restore Report Codepad Fire ReportSystem Status Low Battery Restore Report System Status Low Battery ReportSystem Status Access Denied System Status Reporting OptionsProgrammable Outputs ICP-CC488 Installation Guide Programmable OutputsTest Reporting Dialer Options Output Event Types Redirecting Outputs to the Codepad BuzzerExit Warning + Entry Warning + Day Alarm Resetting Entry Warning + Day Alarm ResettingDay Alarm Enabled AUX Power Supply FailCodepad Medical Alarm Sensor Watch AlarmCodepad Fire Alarm Codepad Panic AlarmRemote Control Fire Alarm VerificationRadio Control Output 1 Not in Away Mode Radio Control Output 2 Not in Away ModeMimic Zone Area 1 in Alarm Area 2 in AlarmGlobal Chime Zone Not SealedOutput Polarity ICP-CC488 Installation Guide System Event Timers System Event TimersOutput Timing Pulsing PolaritiesEntry Timer Programming Entry/Exit TimersExit Timer Entry Guard Timer for Stay ModeCodepad Lockout Time Auto Arming Pre-Alert TimerSiren Run Time Siren Sound RateSystem and Consumer Options Access Denied Code Retries To Be Silent Assign Button 4 To Operate Stay ModeStrobe Indications for Radio Arm/Disarm Codepad Panic To Be SilentConsumer Options Radio Input Options ICP-CC488 Installation Guide Partitioning Using Codepads in a Partitioned SystemPartitioning 19.1 CP500 Master Partitioned LED CodepadZone Allocations User Code Allocations Setting Up and Programming Codepads for PartitioningZone Allocations for Areas 1 Detailed ExampleSetting Up an Area 1 Codepad Setting Up an Area 1 Codepad as the Main CodepadSetting Up an Area 2 Codepad Codepad Connections For Partitioning ExamplesRF Information ICP-CC488 Installation Guide RF InformationRF Option Bit Default RF Device Mapping Devices 9 to Default RF Device Mapping Devices 1 toUsing Hexadecimal Values for RF Device Mapping Enable RF Jamming MonitorRF Device Signal Strength Devices 9 to 16 Read Only RF Device Signal Strength Devices 1 to 8 Read OnlyICP-CC488 Installation Guide Optional Equipment Optional Equipment21.3 SS914 Edmsat Satellite Siren 21.5 CC816 Alarm Link Software21.4 CC891 Programming Key ICP-CP500AW Eight Zone Area Addressable CodepadTerminals and Descriptions ICP-CC488 Installation Guide Terminals and DescriptionsTerminal Descriptions Glossary Of Terms That an alarm was sent out Domestic alarm reportsStay Mode This mode. Only the installer can program these zonesICP-CC488 Wiring Diagram DiagramsICP-CC488 Installation Guide Terminals and Descriptions Telecom Connection Diagram for Australia Wiring and Power Up OperationYellow wire Green wire ICP-CC488 Installation Guide Appendices Appendix B Test Reports Only When ArmedAppendices Appendix a Telephone Anti JammingWarranty Statement SpecificationsSpecifications Software Version NumberProgramming Sheets ICP-CC488 Installation Guide Programming SheetsTick ICP-CC488 Programming SheetsAlarm Link Options Telephone Line Fault OptionsDialing Format ReservedDay Alarm Zones Installer CodeUser Code Priority Levels EOL Resistor ValueZones Zone Pulse Count SettingsRF Receiver Trouble Restore Report RF Low Battery ReportZone Descriptions Swinger Shutdown Count for SirenSystem Status AUX Power Supply Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AC Fail Restore Report System Status Low Battery ReportDelay Alarm Reporting Time Entry Guard Time for Stay ModeSpeaker Beep Volume Sensor Watch TimeRadio Input Options Zone Allocations Enabled for Area 1 and AreaZone Allocations for Area 1 and Area Domestic Telephone NumbersRF Device Signal Strength Devices 9 to RF Device Signal Strength Devices 1 toRF Options RF Device Mapping OptionCountry Codes Disable Factory DefaultSystem Time System DateICP-CC488 Installation Guide Programming Sheets ICP-CC488 Installation Guide Index Remote Connect Without Call Back Verification41 IndexTelephone Line Fault Options 52, 80 Disarming ICP-CC488 Installation Guide Index Enable User Code + 0 + Away To Arm/Disarm Zone Restore Code Bosch Security Systems, Inc. F01U089457-02