| Programming Sheets |
|
|
EN 107
Entry Guard Time for STAY Mode
Location | 472 to 473 | Refer to page 78 | |
Default |
| 0 0 | |
Location 472 | Increments of 1 sec (0 to 15 sec) | ||
Location 473 | Increments of 16 sec (0 to 240 sec) |
Delay Alarm Reporting Time
Location | 474 to 475 | Refer to page 78 | |
Default |
| 0 0 | |
Location 474 | Increments of 1 sec (0 to 15 sec) | ||
Location 475 | Increments of 16 sec (0 to 240 sec) | ||
|
|
|
|
Sensor Watch Time
Location | 476 to 477 | Refer to page 66 | |
Default |
| 0 0 | |
Location 476 | Increments of days (tens digit) | ||
Location 477 | Increments of days (units digit) |
Codepad Lockout Time
Location | 478 | Refer to page 79 |
Default | 0 | |
Location 478 | Increments of 10 sec | |
|
|
|
Siren Run Time
Location | 479 | Refer to page 79 |
Default | 5 | |
Location 479 | Increments of 1 minute |
Siren Sound Rate (Slow <- Sound -> Fast)
Location | 480 | Refer to page 79 |
Default | 7 | |
|
|
|
Auto Arming Pre-Alert Time
Location | 481 | Refer to page 79 |
Default | 1 | |
Location 481 | Increments of 5 min |
Auto Arming Time
Location | 482 to 485 | Refer to page 79 | |
Default |
| 0 0 0 0 | |
Location 482 | Hour of the day – tens digit | ||
Location 483 | Hour of the day – units digit | ||
Location 484 | Minute of the day – tens digit | ||
Location 485 | Minute of the day – units digit |
Auto Disarming Time
Location | 486 to 489 | Refer to page 79 | |
Default |
| 0 0 0 0 | |
Location 486 | Hour of the day – tens digit | ||
Location 487 | Hour of the day – units digit | ||
Location 488 | Minute of the day – tens digit | ||
Location 489 | Minute of the day – units digit |
Kiss-Off Wait Time
Location | 490 | Refer to page 80 |
Default | 3 | |
Location 490 | Increments of 500 ms |
Speaker Beep Volume
Location |
| 491 |
| Refer to page 80 |
Default |
|
| 13 | |
0 |
| No beeps |
|
|
15 | Loudest beeps |
|
|
System Options 1
Location |
| 492 |
| Refer to page 80 |
1Bosch Security Systems, Inc. smart lockout allowed
2 Horn speaker monitor
4 Strobe indications for radio arm/disarm
8Assign button 4 on transmitter to operate STAY Mode 1
System Options 2
Location | 493 | Refer to page 81 |
Default 0
1Codepad Panic to be silent
2 Codepad Fire to be silent
4 Codepad Medical to be silent
8 Access denied (code retries) to be silent
System Options 3
Location | 494 | Refer to page 81 |
1AC fail after 1 hour (disabled – after 2 min)
2 Ignore AC fail
4 Pulse count handover allowed
8 Handover delay to be sequential
System Options 4
Location | 495 | Refer to page 82 |
Default | 0 |
|
1Panel to power up disarmed (if power reset)
2 Arm/disarm tracking on power up
4 Internal crystal to keep time
8 Night arm station, or RE005 installed
Consumer Options 1
Location | 496 | Refer to page 82 |
Default | 0 |
|
1Test reports only when armed
2 Test report after siren reset
4 Auto arm in STAY Mode 1
8 STAY indicator to display Day Alarm status
Consumer Options 2
Location | 497 | Refer to page 83 |
1Codepad display extinguishes after 60 sec
2Single button arming allowed (AWAY/STAY Modes 1 and 2)
4Single button disarming allowed (STAY Modes 1 and 2)
8Alarm memory reset on disarm