| Dialer Reporting Formats |
|
|
EN 45
Table 42: 4 + 2 Transmission Code
Descriptions
Code Description
SSSS Subscriber ID Number
AAlarm
CH | Channel Number1 |
0Zero
TTrouble
BBypass
EAC Fail Code 1st digit
AC | AC Fail Code 2nd digit |
LLow Battery Code 1st digit
L | B | Low Battery Code 2nd digit |
OOpen
CClose
UUser Number
RAlarm Restore Code
TR | Trouble Restore Code |
BR | Bypass Restore Code |
E | AC Fail Restore Code 1st digit |
R |
|
ACR | AC Fail Restore Code 2nd digit |
L | Low Battery Restore Code 1st digit |
R |
|
L | Low Battery Restore Code 2nd digit |
BR |
|
DDuress Code 1st digit
D | 0 | Duress Code 2nd digit |
PPanic Code 1st digit
P | Panic Code 2nd digit |
CH |
|
TE | Test Code |
10=Zone 16, 1=Zones 1 through 15. Some receivers might need to have parameters set to 0 for Zone 16
10.1.5Basic Pager Reporting Format
Although Basic Pager Format requires some interpretation of the numbers that appear on the display, it is possible to differentiate among 1000 different control panels if a number of control panels report to the one pager.
To set up Receiver 1 for basic pager reporting:
1.Program the Basic Pager’s access telephone number in Locations 000 to 015 (refer to Section 11.1 Primary Telephone Number for Receiver 1 and Receiver 2 on page 49).
2.Program the Subscriber ID Number in Locations 034 to 039 (refer to Section 11.5 Subscriber ID Number for Receiver 1 and Receiver 2 on page 50).
3.Select the Pager Handshake option (5) in Location 032 (refer to Section 11.3 Handshake Tone for Receiver 1 and Receiver 2 on page 49).
4.Program the Basic Pager Format option (5) in Location 033 (refer to Section 11.4 Transmission Format for Receiver 1 and Receiver 2 on page 50).
To set up Receiver 2 for basic pager reporting:
1.Program the Basic Pager’s access telephone number in Locations 040 to 055 (refer to Section 11.1 Primary Telephone Number for Receiver 1 and Receiver 2 on page 49).
2.Program the Subscriber ID Number in Locations 074 to 079 (refer to Section 11.5 Subscriber ID Number for Receiver 1 and Receiver 2 on page 50).
3.Select the Pager Handshake option (5) in Location 072 (refer to Section 11.3 Handshake Tone for Receiver 1 and Receiver 2 on page 49).
4.Program the Basic Pager Format option (5) in Location 073 (refer to Section 11.4 Transmission Format for Receiver 1 and Receiver 2 on page 50).
The example in Figure 9 on page 47 shows:
•A transmission from Subscriber ID Number 5678
•Zone 2 is in alarm
•Zone 3 is manually isolated
•The system is armed
•The Panic Zone is normal
•The AC is connected
•There is no fault condition.