| System Reporting Information |
|
|
EN 68
Restore Reports are not sent for this event.
If Codepad Panic Reports are not required, program Locations 405 and 406 as 0.
15.17 Codepad Fire Report
Location | 407 to 408 |
|
| Location | Default |
Tens digit | 407 | 7 |
Units digit | 408 | 14 |
|
|
|
A Fire Alarm Report (Contact ID Event Code 110) is sent to the base station receiver when a user presses
[4]and [6] at the same time. A Fire Alarm is audible, but you can program the alarm as silent by selecting Option 2 in Location 493 (refer to Section 18.2 System Options 2 on page 81). A distinct fire sound is emitted through the horn speaker to indicate this type of alarm. The fire sound is different than the burglary sound.
Restore Reports are not sent for this event.
If Codepad Fire Reports are not required, program Locations 407 and 408 as 0.
15.18 Codepad Medical Report
Location | 409 to 410 |
|
| Location | Default |
Tens digit | 409 | 7 |
Units digit | 410 | 13 |
|
|
|
A Medical Report (Contact ID Event Code 100) is sent to the base station receiver when a user presses
[7]and [9] at the same time. A Medical Alarm is
audible, but you can program the alarm as silent by selecting Option 4 in Location 493 (refer to Section 18.2 System Options 2 on page 81).
Restore Reports are not sent for this event.
If Codepad Medical Reports are not required, program Locations 409 and 410 as 0.
15.19 Codepad Reporting Options
Location 411
0No Codepad Alarm Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
Location 411 is set by default to report only to Receiver 1. You can select whether Codepad Alarm Reports are sent to Receiver 1, Receiver 2, or both, Receiver 2 only when Receiver 1 fails, or no reporting.
15.20System Status – AUX Power Supply Fail Report
Location | 412 to 413 |
|
| Location | Default |
Tens digit | 412 | 10 |
Units digit | 413 | 3 |
|
|
|
A System Trouble Report (Contact ID Event Code
300)is sent when either the codepad AUX power supply is blown or the AUX power supply malfunctions. The system reports the event approximately 10 sec after the failure.
15.21System Status – AUX Power Supply Fail Restore Report
Location | 414 to 415 |
|
| Location | Default |
Tens digit | 414 | 10 |
Units digit | 415 | 8 |
|
|
|
A System Trouble Restore Report (Contact ID Event Code 300) is sent when the AUX power supply is reset. The system reports the event approximately 10 sec after power supply is reset.
15.22 System Status – AC Fail Report
Location | 416 to 417 |
|
| Location | Default |
Tens digit | 416 | 10 |
Units digit | 417 | 2 |
An AC Fail Report (Contact ID Event Code 301) is sent to the base station receiver when the AC MAINS supply is disconnected for 2 min. If you do not want an AC Fail Report to be sent until the AC MAINS supply is disconnected for 1 hour, select Option 1 in Location 494 (refer to Section 18.3 System Options 3 on page 81). If you want to ignore AC Fail, select Option 2 in Location 494.
If AC Fail Reports are not required, program Locations 416 and 417 as 0.
15.23System Status – AC Fail Restore Report
Location | 416 to 417 |
|
| Location | Default |
Tens digit | 416 | 10 |
Units digit | 417 | 7 |
An AC Fail Restore Report is sent when the AC MAINS supply is connected continuously for longer than 2 min.
If AC Fail Restore Reports are not required, program Locations 418 and 419 as 0.