| Programmable Outputs |
|
|
EN 72
0,12 Entry Warning + Day Alarm Resetting
This output combines Entry Warning and Day Alarm Resetting so that either of these two events activates the output.
If the output is activated by Entry Timer 1, Entry Timer 2, or Entry Guard Timer for STAY Mode, the output is reset when the Entry Time expires or the system is disarmed.
If a zone programmed for Day Alarm is activated when the system is disarmed, the output is reset when the zone is resealed. You can turn Day Alarm on and off by holding down [4]. Refer to Section 14.1 Day Alarm Information for programming zones to operate for Day Alarm.
0,13 Exit Warning + Entry Warning + Day Alarm Resetting
This output operates when the system is armed, regardless of whether zones are sealed or unsealed, until Exit Time expires.
The output operates again during Entry Time and is reset when Entry Time expires or the system is disarmed. The output also operates during the Entry Guard Timer for STAY Mode time.
If a zone programmed for day alarm is activated when the system is disarmed, the output is reset when the zone is resealed. You can turn Day Alarm on and off by holding down [4]. Refer to Section 14.1 Day Alarm Information for programming zones to operate for Day Alarm.
0,14 Day Alarm Resetting
This output operates when a zone programmed for Day Alarm is activated. The output is reset when the Day Alarm zone is resealed. You can turn Day Alarm on and off by holding down [4]. Refer to Section 14.1 Day Alarm Information for programming zones to operate for Day Alarm.
0,15 Day Alarm Latching
This output operates when a zone programmed for Day Alarm is activated. The output is reset by pressing [AWAY]. You can turn Day Alarm on and off by holding down [4]. Refer to Section 14.1 Day Alarm Information on page 56 for programming zones to operate for Day Alarm.
If the
1,0 Day Alarm Enabled
This output operates when Day Alarm is enabled. The output is reset when Day Alarm is turned off. Refer to Section 14.1 Day Alarm Information on page 56 for programming zones to operate for Day Alarm.
You can turn Day Alarm on and off by holding down [4]. Three beeps indicate that Day Alarm is turned on, two beeps indicate that Day Alarm is turned off. Refer to Section 5.4.7 Turning Day Alarm On and Off on page 33 for more information.
1,1 Telephone Line Fail
This output operates when the
1,2 Kiss-off Received
This output operates after the control panel successfully transmitted to the receiving party.
1,3 AUX Power Supply Fail
This output operates when either the 1 A codepad AUX power supply or the 1 A accessories AUX power supply fails. The output is reset when the faulty AUX power supply is reset.
1,4 | AC Fail |
This output operates when the AC MAINS fails. The output is reset when the AC MAINS is restored. This output operates regardless of whether Option 2 in Location 494 is selected (refer to Section 18.3 System Options 3 on page 81).
1,5 Low Battery
This output operates when a Dynamic Battery Test detects the battery failed or the battery voltage is below 11.2 VDC. The Dynamic Battery Test is performed every 4 hours after the system is powered up and every time the system is armed.
This output is reset only after a Dynamic Battery Test reports that the backup battery voltage is normal.
1,6 Horn Speaker Monitor Fail
If the Enable Monitoring of Horn Speaker option (2) in Location 492 is selected (refer to Section 18.1 System Options 1 on page 80), this output operates when the horn speaker is disconnected. The output is reset when the horn speaker is reconnected.