| Introduction |
|
|
EN 9
1.2Quick Start
The following steps allow you to use the
After all wiring is complete, connect the AC plug pack to the control panel.
Both the MAINS and AWAY indicators are lit. The MAINS indicator lights to indicate the AC MAINS supply is connected.
The AWAY indicator lights to signify the system is armed in AWAY Mode.
If any
Enter the default Master Code (2580) and press [AWAY] to disarm the system and to reset any alarm that occurred when you powered up the system.
The AWAY indicator is extinguished to signify that the system is disarmed.
If any zone indicator is flashing, an alarm occurred in that zone.
If a zone indicator is lit constantly, the zone is unsealed.
Connect the backup battery.
Enter the default Installer Code (1234) and press [AWAY].
Two beeps sound and the STAY and AWAY indicators flash simultaneously to indicate that you entered Installer’s Programming Mode.
When entering Installer’s Programming Mode, you are automatically positioned at Location 000, the first digit of the Primary Telephone Number for Receiver 1.
Enter the Primary Telephone Number, the Secondary Telephone Number, and the Subscriber ID Number for Receiver 1.
Refer to Sections 11.1, 11.2, and 11.5 for more information about programming these numbers. When programming the telephone numbers for Receiver 1 and Receiver 2, you must program a 0 as a 10. Programming a 0 in the telephone number indicates the end of the dialing sequence. Unless otherwise stated, program a 0 as a 0 in all locations other than the telephone numbers for Receiver 1 and Receiver 2, and the Call Back Telephone Number.
If required, set the Test Report time.
Program any other required changes. Otherwise, factory default settings are used. Refer to Section
15.28Test Reporting Time for more information.
Enter command [9 6 0] and press [AWAY] to exit from Installer’s Programming Mode.
Two beeps sound and the STAY and AWAY indicators are extinguished. The system is returned to the disarmed state and is ready for use. Refer to Section 7.4 Installer’s Programming Commands for more information.
Use the Master Code to set the date and time. Refer to Section 1.2.1 Set the Date and Time for more information.
1.2.1Set the Date and Time
1.Enter your Master Code and press [6][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.
2.Enter the day, month, year, hour, and minute in DD, MM, YY, HH, MM format (where DD is the day of the month, MM is the month of the year, YY is the year, HH is the hour of the day, and MM minute of the day) and press [AWAY]. Use 24:00 hour format when programming the hour of the day.
Two beeps sound and the STAY and AWAY indicators are extinguished. If a long beep sounds, there was an error when you entered the date and time.
Example
To set the date and time for the 1st January 2004 at 10:30 PM, enter:
[2 5 8 0 6][AWAY][0 1 0 1 0 4 2 2 3 0][AWAY]
1.2.2ICP-CC488 Zone Defaults
The default zone settings for the control panel are listed in Table 1 on page 9. You can program Zones 1 to 8 to any of the zone types. Refer to Table 2 on page 10 for the zone types you can select.
Table 1: Zone Defaults for the ICP-CC488
Zone | Zone Type | Zone | Zone Type |
1 | 5 | Instant | |
2 | Handover | 6 | Instant |
3 | Handover | 7 | Instant |
4 | Handover | 8 |