ACTURA Flex 48330 Power System User Manual
Page
Page
Page
Contents
Page
Page
Table List
Figure List
Page
Chapter 1 System Description
1.1 Abbreviation
1.2 Introduction
1.3 Features
1.4 System Configuration
1.5 Components
1.5.1 Rectifier Shelf
Page
1.5.2 Rectifier
1.5.3 SCU
Page
1.5.4 Multi-Function Unit (MFU)
1.5.5 Battery Connection Unit (BCU)
1.5.6 System Cabinet
Chapter 2 Installation
2.1 Installation Preparation
2.1.1 Environmental Conditions
2.1.2 Power Supply
2.1.3 Site Survey
2.1.4 Tools & Material
2.1.5 Unpacking
2.2 Installation Procedures
2.2.1 Cabinet Installation
Page
2.3 External Electrical Connection Interface
2.3.1 Connection Of Input Cables
Page
Page
2.3.2 Connection Of Load Cables
Note
2.3.3 Connection Of Communication Cables
Page
2.3.5 Interface Definition Of Connector Board S6415X2
2.3.6 Connection Of Temperature Sensor Cables
2.3.7 Connection With MODEM
Note
2.3.8 Connection With Dry Contacts
2.4 Battery Installation And Cabling
2.4.1 Battery Installation
Note
2.4.2 Battery Cable Connection
Page
Page
2.5 Parallel Connection Of Cabinets
Chapter 3 Startup
3.1 Checking Before Startup
3.2 Startup Process
Item Action Result Comments (Fill in OK or not)
3.3 Parameters Configuration
Chapter 4 Testing
4.1 Testing MFU
4.2 Testing Rectifier
4.3 Testing SCU
4.4 Battery Breaker Test
4.5 BCU Test
4.6 Load Breaker Test
Chapter 5 Operating SCU
5.1 Operation Panel
5.2 Operation Procedures
5.3 Querying System Status
5.3.1 First Page Of System Information
Note
5.3.2 Other System Information Screen
Note
Page
5.4 Querying Rectifier Status
5.5 Querying Alarms And Setting Alarm Plans
5.5.1 Querying Active Alarm
5.5.2 Query Alarm History
Page
5.5.3 Alarm Type Table
Table 5-3 Alarm type table
Page
Page
Note
5.5.4 Changing Audible/Visual Alarm And Alarm Call Back Plan
5.5.5 Changing Alarm Types Of Dry Contacts
5.5.6 Setting Alarm Type For Dry Contacts
Page
5.5.7 Set the Alarm Names Through PLC Function
Page
PLC SN
Alarm description Remark
5.6 Maintenance
Page
5.7 Setting System Parameters
Page
5.7.2 Batt. Selection
5.7.3 LVD Parameter Description
Note
5.7.4 Charging Management Parameters
Page
3. The BC/FC switchover diagram is shown below:
Figure 5-2 BC/FC switchover diagram
5.7.5 Battery Test Parameters
3. The schematic diagram of the test function is shown below:
Battery Auto-management
Manually start battery test
Rectifier output voltage lower than battery voltage Battery discharges Rectifier hot standby
"Test End Voltage" is reached "Test End Cap" is reached "Test End Time" is reached
5.7.6 Temperature Compensation Coefficient Parameters
Parameter Range Default Value description
5.7.7 AC Settings
1. The configuration interface is shown below:
5.7.8 DC Setting
1. There are three related pages, as shown below:
5.7.9 Rect Settings
5.7.10 System Settings
Page
Table 5-18 Value description of system settings Parameter Range Default Value description
Parameter Range Default Value description
5. The model description is shown below:
Figure 5-4 System model description
48V / 30A / 300 / NO NE
Note
5.7.11 Alarm Settings
Chapter 6 Routine Maintenance
6.1 Maintenance Of Rectifier
6.2 Maintenance Of SCU
6.3 Maintenance Of MFU
6.4 Cover Plates
6.5 Battery Maintenance
6.5.1 Storage And Supplementary
6.5.2 Daily Inspection
6.5.3 Replacement
Chapter 7 Troubleshooting
7.1 Troubleshooting Rectifier
7.2 Mains Failure
7.3 Disastrous Accidents
Appendix 1 System Technical Parameters
Parameter category Note
Page
Page
Appendix 2.3 Engineering Design Diagram For 700mm%600mm%400mm Cabinet
Appendix 2.4 System Input And Output Connector Specs
Page
Page
Page
Page
Appendix 4 Glossary
Abbreviation Full word