Emerson 48330 user manual Llvd, Blvd

Models: 48330

1 96
Download 96 pages 18.86 Kb
Page 54
Image 54

44

Chapter 5 Operating SCU

Serial

Alarm

Description

Default

Default

related

No.

alarm level

 

 

relay

 

 

 

 

 

 

Battery temperature is lower than the

 

 

14

Batt Temp Low

set value of parameter “Temp

Observation

None

 

 

Threshold: Low Temp”

 

 

 

 

 

 

 

15

Amb Temp High

Ambient temperature is higher than

Observation

None

the set alarm point

 

 

 

 

 

 

 

 

 

16

Amb Temp Low

Ambient temperature is lower than

Observation

None

the alarm point

 

 

 

 

 

 

 

 

 

17

No TempSensor1

Temperature sensor 1 has been set,

Critical

None

 

 

but no sensor is actually connected

 

 

18

No TempSensor2

Temperature sensor 2 has been set,

Critical

None

 

 

but no sensor is actually connected

 

 

19

TempSensor1

Temperature sensor 1 detected

Critical

None

Err

unreasonable temperature

 

 

 

 

 

 

 

 

20

TempSensor2 Err

Temperature sensor 2 detected

Critical

None

unreasonable temperature

 

 

 

 

 

 

 

 

 

21

LLVD

1. Load disconnection

Critical

5

2. Manual load disconnection

 

 

 

 

 

 

 

 

 

 

 

1. When battery discharges till its

 

 

 

 

voltage is lower than the “BLVD

 

 

22

BLVD

Volt”, or the discharge time is longer

Critical

4

 

 

than the “BLVD Time”, the BLVD

 

 

 

 

contactor will be open automatically

 

 

 

 

2. BLVD through manual operation

 

 

 

 

 

 

 

23

Load 1 Faiure

Over-load, short circuit, manual

Critical

6

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

24

Load 2 Faiure

Over-load, short circuit, manual

Critical

6

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

25

Load 3 Faiure

Over-load, short circuit, manual

Critical

6

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

26

Load 4 Faiure

Over-load, short circuit, manual

Critical

6

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

27

Load 5 Faiure

Over-load, short circuit, manual

Critical

6

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

28

Load 6 Faiure

Over-load, short circuit, manual

Critical

6

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

29

Load 7 Faiure

Over-load, short circuit, manual

Critical

6

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

30

Load 8 Faiure

Over-load, short circuit, manual

Critical

6

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

31

Load 9 Faiure

Over-load, short circuit, manual

Critical

6

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

32

Aux Load Fails

The last route faulty

Critical

6

33

Batt1 Failure

Over-load, short circuit, manual

Critical

None

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

34

Batt2 Failure

Over-load, short circuit, manual

Critical

None

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

35

Batt3 Failure

Over-load, short circuit, manual

Critical

None

disconnection or alarm circuit faulty

 

 

 

 

 

 

 

 

 

Related parameter

configuration

Low temperature alarm point

LLVD enabled

BLVD enabled

ACTURA Flex 48330 Power System User Manual

Page 54
Image 54
Emerson 48330 user manual Llvd, Blvd