3Com RMON-EMP-3 installation and operation guide 5. Modify/View Serial Configuration Values Menu

Models: RMON-EMP-3

1 120
Download 120 pages 61.92 Kb
Page 56
Image 56
Figure 3-5. Modify/View Serial Configuration Values Menu

Figure 3-5 is an example of the Serial Configuration Values menu options.

Modify/view serial configuration values menu Rev N.NN

1 Serial port IP address

187.187.187.193

2

Serial port subnet mask

255.255.255.192

3

Serial port speed

9600

4

Serial port mode

Direct

5

Modem Init String

^s^MATEOQ0V1X4 S0=1 S2=43^M^d2

6

Modem Hangup String

^d2^s+++^d2^s^ATH0^M^d2

7

Modem Connect Responses

 

/CONNECT/300/CONNECT 1200/1200/CONNECT 2400/2400/CONNECT 4800/4800/CONNECT 9600/9600/CONNECT 14400/14400/CONNECT 19200/19200/CONNECT 38400/38400/

8 Modem No-Connect Responses

/NO CARRIER/BUSY/NO DIALTONE/NO ANSWER/ERROR/

S Save changes and exit

0 Cancel changes and exit

Enter one of: 1 2 3 4 5 6 7 8 S O ?

Figure 3-5. Modify/View Serial Configuration Values Menu

3 - 14 Ethernet RMON MultiProbe Module Installation and Operation Guide

Page 56
Image 56
3Com RMON-EMP-3 installation and operation guide 5. Modify/View Serial Configuration Values Menu