3Com RMON-EMP-3 installation and operation guide 2. Troubleshooting Malfunctions

Models: RMON-EMP-3

1 120
Download 120 pages 61.92 Kb
Page 89
Image 89
Troubleshooting Malfunctions

Troubleshooting Malfunctions

Table 4-2 lists the symptoms of operating malfunctions for the RMON MultiProbe Module and shows possible causes and corrective actions for these malfunctions.

Table 4-2. Troubleshooting Malfunctions

Symptom

Possible Cause

Corrective Action

 

 

 

Module Status LED

An unrecoverable

Contact the 3Com

does not illuminate

error in the module

Customer Service Center.

or blink

hardware or

 

 

software has

 

 

occured.

 

 

 

 

Module Status LED

Interprocessor

Press the Reset button on

blinks continuously

failure.

the front panel to reset

 

 

the module.

 

 

 

Module Status LED

68030 diagnostics

Contact the 3Com

illuminates briefly

failed.

Customer Service Center.

and then remains

 

 

off

 

 

 

 

 

Module Status LED

i960 diagnostics

Attach a terminal to the

blinks continuously

failed.

module RS-232 port.

 

 

Reset the module. Note

 

 

the failure code. Contact

 

 

the 3Com Customer

 

 

Service Center.

 

 

 

Troubleshooting 4 - 3