3Com RMON-EMP-3 BOOTP Requirements, Using BOOTP, Sample BOOTPtab file

Models: RMON-EMP-3

1 120
Download 120 pages 61.92 Kb
Page 72
Image 72

To configure other interfaces, use the Modify/View Network Settings configuration menu to change the BOOTP network interface.

BOOTP Requirements

The BOOTP server must perform the following functions:

Map hardware addresses to IP addresses

Respond to BOOTP requests from clients

Support the vendor-specific subnet mask and default gateway fields

Using BOOTP

To use BOOTP, add the following information to the BOOTP server bootptab configuration file:

MAC address - Hardware address of the RMON MultiProbe Module interface to be configured

IP address - IP address for the module interface

Subnet mask - Subnet mask for the module interface

Default gateway - Default gateway for the RMON MultiProbe Module

For additional information on BOOTP configurations, refer to your server documentation.

Sample BOOTPtab file

A sample bootptab file is shown on the next page. If necessary, create this file on the BOOTP server.

3 - 30 Ethernet RMON MultiProbe Module Installation and Operation Guide

Page 72
Image 72
3Com RMON-EMP-3 installation and operation guide BOOTP Requirements, Using BOOTP, Sample BOOTPtab file