Management Command Examples

To assign interface 1 on the RMON MultiProbe Module in slot 7 to Ethernet 1, use the following network management command:

SET PORT 7.1 NETWORK ETHERNET_1

Port 07.01 network id set to ETHERNET_1.

To assign interface 1 to isolated, use the following command:

SET PORT 7.1 NETWORK ISOLATED

Port 07.01 network id set to ISOLATED.

To assign interface 3 on the RMON MultiProbe Module in slot 7 to Ethernet 3, use the following network management command:

SET PORT 7.3 NETWORK ETHERNET_3

Port 07.03 network id set to ETHERNET_3.

You cannot assign an interface to a network other than its corresponding network. For example, a management module aborts the following command:

SET PORT 7.3 NETWORK ETHERNET_1

Port 3 can only be set to ETHERNET_3 or ISOLATED: command aborted.

3 - 36 Ethernet RMON MultiProbe Module Installation and Operation Guide

Page 78
Image 78
3Com RMON-EMP-3 installation and operation guide Management Command Examples, SET Port 7.1 Network ETHERNET1