Management Command Examples
To assign interface 1 on the RMON MultiProbe Module in slot 7 to Ethernet 1, use the following network management command:
SET PORT 7.1 NETWORK ETHERNET_1
Port 07.01 network id set to ETHERNET_1.
To assign interface 1 to isolated, use the following command:
SET PORT 7.1 NETWORK ISOLATED
Port 07.01 network id set to ISOLATED.
To assign interface 3 on the RMON MultiProbe Module in slot 7 to Ethernet 3, use the following network management command:
SET PORT 7.3 NETWORK ETHERNET_3
Port 07.03 network id set to ETHERNET_3.
You cannot assign an interface to a network other than its corresponding network. For example, a management module aborts the following command:
SET PORT 7.3 NETWORK ETHERNET_1
Port 3 can only be set to ETHERNET_3 or ISOLATED: command aborted.