Warm-Starting the RMON MultiProbe Module

When you re-initialize the RMON MultiProbe Module by initiating a warm start (for example, by pressing the Reset button), all collected information stored in the module Random Access Memory (RAM) is lost. Configuration information, however, is not lost. Table 3-10 lists the information preserved and lost upon a warm start of the module.

Table 3-10. RMON MultiProbe Module Information Preserved and Lost on Warm Start

Information Preserved

Information Lost

 

 

All installed filter and channel tables

Captured Packets

 

 

Buffer Control Table

Counted Packets

 

 

History Control Table

Historical Ethernet Statistics

 

 

Alarm Table

Current Ethernet Statistics

 

 

Event Table

Matrix Tables

 

 

Community Access Table Entries

Host Top N Tables

 

 

Client Table Entries

Host Tables

 

 

Module Configuration Entries

Logs

(IP Address, Subnet Mask)

 

 

 

TFTP Server Address

 

 

 

Download Filename

 

 

 

Time Zone

 

 

 

Serial Port Configuration

 

Information

 

 

 

Serial Connection Table

 

 

 

Trap Destination Table

 

 

 

Configuring the Module 3 - 41

Page 83
Image 83
3Com RMON-EMP-3 Warm-Starting the Rmon MultiProbe Module, Information Preserved Information Lost