3 Configuring the Switch

CLI – Enter Line Configuration mode for a virtual terminal, then specify the connection parameters as required. To display the current virtual terminal settings, use the show line command from the Normal Exec level.

Console(config)#line vty

4-11

Console(config-line)#login local

4-12

Console(config-line)#password 0 secret

4-13

Console(config-line)#timeout login response 300

4-14

Console(config-line)#exec-timeout 600

4-14

Console(config-line)#password-thresh 3

4-15

Console(config-line)#end

 

Console#show line

 

4-19

Console configuration:

 

 

Password threshold:

3 times

 

Interactive timeout:

Disabled

 

Login timeout:

Disabled

 

Silent time:

Disabled

 

Baudrate:

9600

 

Databits:

8

 

Parity:

none

 

Stopbits:

1

 

VTY configuration:

 

 

Password threshold:

3 times

 

Interactive timeout:

600 sec

 

Login timeout: 300 sec

Console#

Configuring Event Logging

The switch allows you to control the logging of error messages, including the type of events that are recorded in switch memory, logging to a remote System Log (syslog) server, and displays a list of recent event messages.

System Log Configuration

The system allows you to enable or disable event logging, and specify which levels are logged to RAM or flash memory.

Severe error messages that are logged to flash memory are permanently stored in the switch to assist in troubleshooting network problems. Up to 4096 log entries can be stored in the flash memory, with the oldest entries being overwritten first when the available log memory (256 kilobytes) has been exceeded.

The System Logs page allows you to configure and limit system messages that are logged to flash or RAM memory. The default is for event levels 0 to 3 to be logged to flash and levels 0 to 6 to be logged to RAM.

Command Attributes

System Log Status – Enables/disables the logging of debug or error messages to the logging process. (Default: Enabled)

Flash Level – Limits log messages saved to the switch’s permanent flash memory for all levels up to the specified level. For example, if level 3 is specified, all messages from level 0 to level 3 will be logged to flash. (Range: 0-7, Default: 3)

3-28

Page 72
Image 72
Accton Technology ES3526XA, ES3552XA manual Configuring Event Logging, System Log Configuration