4 Command Line Interface

timeout login response

This command sets the interval that the system waits for a user to log into the CLI. Use the no form to restore the default.

Syntax

timeout login response [seconds] no timeout login response

seconds - Integer that specifies the timeout interval. (Range: 0 - 300 seconds; 0: disabled)

Default Setting

CLI: Disabled (0 seconds)

Telnet: 600 seconds

Command Mode

Line Configuration

Command Usage

If a login attempt is not detected within the timeout interval, the connection is terminated for the session.

This command applies to both the local console and Telnet connections.

The timeout for Telnet cannot be disabled.

Using the command without specifying a timeout restores the default setting.

Example

To set the timeout to two minutes, enter this command:

Console(config-line)#timeout login response 120

Console(config-line)#

Related Commands

silent-time(4-16)exec-timeout (4-14)

exec-timeout

This command sets the interval that the system waits until user input is detected. Use the no form to restore the default.

Syntax

exec-timeout [seconds] no exec-timeout

seconds - Integer that specifies the number of seconds. (Range: 0-65535 seconds; 0: no timeout)

Default Setting

CLI: No timeout

Telnet: 10 minutes

4-14