Configuring with an ASCII Terminal

UPDATING THE CAMPUS-REX FIRMWARE

Before you can upgrade a Campus-RS unit, you must first download the firmware file(s) to your computer. These files are available on the ADC Web site, www.adc.com.

1From the Main Menu, type 4 then press ENTER . The Diagnostics menu displays.

May 3, 1999

ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx

13:29:35

Local Unit ID:

Campus-REX

Unit

#34

Local I/F:

REX

Remote Unit ID: Campus-REX

Unit

#12

Remote I/F: REX

Circuit ID:

Network Extension Circuit 5001

 

 

DIAGNOSTICS MENU

1)LOOPBACK SETTINGS MENU

2)DOWNLOAD MODE

(R)eturn

ENTER CHOICE>

2Type 2 and press ENTER to select Download Mode.

3Type Y and press ENTER to confirm the selection.

The console freezes and the Test LED on the line unit or desktop unit front panel illuminates, indicating that the Campus-RS unit is in Download Mode.

4Close the terminal emulation program you are using for the ASCII terminal.

5Start the Download Utility (DNL32.exe).

5-24

Campus-REX RS Interface Card User Manual