Configuring and Monitoring through the LCD

Configuring the Alarm

To enable or disable the local Loss of Signal alarm:

1From the CURRENT ALARMS display, press Next twice. LOCAL I/F ALARMS CONFIG & STATUS displays.

2Press Enter. The current status of the local alarm displays.

3 Press Next. LOC LOSS OF SIG ALM displays.

4Press Enter.

5Press Next to scroll through the settings for the alarm.

6Press Enter to select the desired setting. LOC LOSS OF SIG ALM displays.

Remote Alarms

Loss of Signal (LOS) alarms can occur on the remote unit. This section describes how to view and configure this alarm.

Viewing Current Alarms

If the CURRENT ALARMS display indicates a remote alarm, you can determine the alarm type:

1From the CURRENT ALARMS display, press Next three times. RMT I/F ALARMS CONFIG & STATUS displays.

2Press Enter. The current status of the remote alarm displays.

Campus-REX RS Interface Card User Manual

4-9