Configuring with an ASCII Terminal

6Click Comm, Comm Port, then select the COM port to which the Campus-RS unit is connected.

7Click Comm, Baud Rate, 9600.

8Click Protocol, DNL Mode.

9In the DNL Mode Options box, set the DNL Rate to Standard.

10In the DNL Mode Options box, set the Destination to Local.

11Select the directory and file you want to copy to the Campus-RS unit. The path and file name display in the Firmware File to Upload box.

12Click Start Upload.

Within 20 seconds, a status bar displays to indicate upload progress. When the upload is complete, the unit resets and terminates Download Mode. If the Test LED remains lit, indicating that the unit is still in Download Mode, the file was not copied successfully. Repeat the procedure until the copy is successful.

13Follow the steps in “Returning Configuration Options to Default Values” on page 5-5to restore the Campus-RS unit configuration options to their default values.