Configuring with an ASCII Terminal

2Type 2 then press ENTER . The SNMP Configuration menu displays.

May 3, 1999

ADC DSL SYSTEMS INC.,

CAMPUS RS,

Version x.xx

13:18:03

Local Unit ID:

 

Campus-REX

Unit

#34

 

Local I/F:

REX

Remote Unit ID:

Campus-REX

Unit

#12

 

Remote I/F: REX

Circuit ID:

 

Network Extension Circuit 5001

 

 

 

 

 

 

SNMP CONFIGURATION

 

1)SNMP Read Only Community String: public

2)SNMP Read/Write Community String: private

3)

Authentication Trap Status:

Disabled

(Disabled, Enabled)

4)

Trap Receiver 1

IP

Address:

0.0.0.0

 

5)

Trap Receiver 1

Community

String:

public

 

6)

Trap

Receiver

2

IP

Address:

0.0.0.0

 

7)

Trap

Receiver

2

Community

String:

public

 

(R)eturn

ENTER CHOICE>

3Continue with the following sections to enter the required parameters and, if desired, enable authentication error trap generation.

Entering Required SNMP Parameters

To set the required parameters:

1From the SNMP Configuration menu, type 1 then press ENTER . The system prompts you to enter the Read Only Comm String.

2Type Public, or another string of up to 32 characters then press ENTER . The SNMP Configuration menu displays.

3Type 2 then press ENTER . The system prompts you to enter the Read Write Comm String.

4Type Private, or another string of up to 32 characters as prompted then press ENTER . The SNMP Configuration menu displays.

5-8