Monitoring with an ASCII Terminal
2Type 4 then press ENTER . The Local Alarm History screen displays.
May 3, 1999 | ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx | 13:15:34 | |||||
Local Unit ID: |
| Local I/F: REX |
|
| |||
Remote Unit ID: |
| Remote I/F: REX |
|
| |||
Circuit ID: | Network Extension Circuit 5001 |
|
|
| |||
|
|
| LOCAL ALARM HISTORY |
|
|
| |
Type |
| Current | First | Last |
| Count | |
HDSL Link, | ACTIVE | Dec 09, | Nov 31, | 1 | |||
ES, | OFF |
|
|
|
| 0 | |
ES, | OFF |
|
|
|
| 0 | |
Margin, | OFF |
|
|
|
| 0 | |
Margin, | OFF |
|
|
|
| 0 | |
LOS, | Port | OFF |
|
|
|
| 0 |
Last Cleared: | None |
|
|
|
|
| |
|
| (S)witch to Remote Alarm History |
|
| |||
|
|
| (U)pdate | (C)lear |
|
|
|
|
|
| (R)eturn | (M)ain Menu |
|
|
|
ENTER CHOICE> |
|
|
|
|
|
|
|
This screen shows alarm history of the local unit. If the HDSL line uses two loops, the screen includes information for both loops. The screen includes information on the following alarms:
•Errored seconds (ES)
•Margin
•Loss of Signal (LOS)
To view remote alarm history, type S then press ENTER .
To update the information, type U then press ENTER .
To clear the information, type C then press ENTER .
Alarm history information is lost when power is removed from the Campus unit.