Configuring and Monitoring through the LCD
ViewingYou can view the number of HDSL alarm conditions that have occurred over the past 24 hours. The LCD displays
•local errored seconds (LOCAL ES)
•remote errored seconds (REMOTE ES)
•local unavailable seconds (LOCAL UAS)
•remote unavailable seconds (REMOTE UAS)
You may also view the time when the counter was last cleared and clear the counter.
To view the HDSL alarm history:
1Press Escape until CAMPUS RS I/F: REX displays.
2 Press Next. HDSL LINK CONFIG & STATUS displays.
3Press Enter, then press Next until PERFORMANCE STATUS displays.
4Press Enter, then press Next to scroll through the alarm history displays.
5To reset the counter, press Next until Press ENTER to clear error cnts displays, then press Enter.
AutoSync AlarmsThe system generates an AutoSync alarm if the HDSL Operating Mode is set to AutoSync and an HDSL connection cannot be established in AutoSync Mode. This alarm is generated even if the HDSL link is eventually established through Fallback Mode. This section describes how to view and configure this alarm.