Configuring and Monitoring through the LCD
Viewing Current Alarms
1From the CURRENT ALARMS display, press Next until
HDSL LINK ALARMS displays.
2Press Enter until the current HDSL alarm status displays.
3Press Next until AUTOSYNC: displays.
4If the AutoSync alarm is on or acknowledged, press Enter for more information.
Configuring the Alarm
1From the CURRENT ALARMS display, press Next until
HDSL LINK ALARMS displays.
2Press Enter until the current HDSL alarm status displays.
3Press Next until AUTOSYNC CFG ALM displays.
4Press Enter.
5Press Next to scroll through the settings for the AutoSync alarm until the desired setting displays.
6Press Enter to select the desired setting. AUTOSYNC CFG ALM displays.
Local AlarmsLoss of Signal (LOS) alarms can occur on the local unit. This section describes how to view and configure this alarm.
Viewing Current Alarms
If the CURRENT ALARMS display indicates a local alarm, you can determine the alarm type:
1From the CURRENT ALARMS display, press Next twice. LOCAL I/F ALARMS CONFIG & STATUS displays.
2Press Enter. The current status of the local alarm displays.