Configuring with an ASCII Terminal
May 3, 1999 | ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx | 13:18:50 | |||
Local Unit ID: | Unit | #34 | Local I/F: | REX | |
Remote Unit ID: | Unit | #12 | Remote I/F: REX | ||
Circuit ID: | Network Extension Circuit 5001 |
|
|
SYSTEM PARAMETERS
1)Change System Time
2)Change System Date
3)Change Unit ID
4)Change Circuit ID
5)Change Password
6) | HDSL ES Alarm Threshold: | Disabled | (Disabled, 17, 170) |
7) | HDSL Margin Alarm Threshold: | Disabled |
|
8) | Autosync Configuration Alarm: | Enabled | (Enabled, Disabled) |
9) | Local Data Port LOS Alarm: | Disabled | (Disabled, Enabled) |
10) | Remote Data Port LOS Alarm: | Disabled | (Disabled, Enabled) |
11) | RESET TO FACTORY DEFAULT |
|
|
| (R)eturn | (M)ain Menu |
|
ENTER CHOICE>
3To configure the HDSL ES Alarm Threshold, type 6 then press ENTER . The System Parameters menu shows the new HDSL ES Alarm Threshold setting. Repeat this step until the desired setting displays.
4To configure the HDSL Margin Alarm Threshold, type 7 then press
ENTER .
5Type the desired margin threshold value, or D to disable, then press
ENTER . The System Parameters menu shows the new HDSL Margin Threshold setting. Repeat this step until the desired setting displays.
6To enable or disable the AutoSync alarm, type 8 then press ENTER . The System Parameters menu shows the new AutoSync alarm setting. Repeat this step until the desired setting displays.
7To enable or disable the local LOS alarm, type 9 then press ENTER . The System Parameters menu shows the new Alarm on Local I/F LOS setting. Repeat this step until the desired setting displays.
8To enable or disable the remote LOS alarm, type 1 0 then press ENTER . The System Parameters menu shows the new Alarm on Remote
I/F LOS setting. Repeat this step until the desired setting displays.