Configuring with an ASCII Terminal

May 3, 1999

ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx

13:18:50

Local Unit ID:

Campus-REX

Unit

#34

Local I/F:

REX

Remote Unit ID: Campus-REX

Unit

#12

Remote I/F: REX

Circuit ID:

Network Extension Circuit 5001

 

 

SYSTEM PARAMETERS

1)Change System Time

2)Change System Date

3)Change Unit ID

4)Change Circuit ID

5)Change Password

6)

HDSL ES Alarm Threshold:

Disabled

(Disabled, 17, 170)

7)

HDSL Margin Alarm Threshold:

Disabled

 

8)

Autosync Configuration Alarm:

Enabled

(Enabled, Disabled)

9)

Local Data Port LOS Alarm:

Disabled

(Disabled, Enabled)

10)

Remote Data Port LOS Alarm:

Disabled

(Disabled, Enabled)

11)

RESET TO FACTORY DEFAULT

 

 

 

(R)eturn

(M)ain Menu

 

ENTER CHOICE>

3To configure the HDSL ES Alarm Threshold, type 6 then press ENTER . The System Parameters menu shows the new HDSL ES Alarm Threshold setting. Repeat this step until the desired setting displays.

4To configure the HDSL Margin Alarm Threshold, type 7 then press

ENTER .

5Type the desired margin threshold value, or D to disable, then press

ENTER . The System Parameters menu shows the new HDSL Margin Threshold setting. Repeat this step until the desired setting displays.

6To enable or disable the AutoSync alarm, type 8 then press ENTER . The System Parameters menu shows the new AutoSync alarm setting. Repeat this step until the desired setting displays.

7To enable or disable the local LOS alarm, type 9 then press ENTER . The System Parameters menu shows the new Alarm on Local I/F LOS setting. Repeat this step until the desired setting displays.

8To enable or disable the remote LOS alarm, type 1 0 then press ENTER . The System Parameters menu shows the new Alarm on Remote

I/F LOS setting. Repeat this step until the desired setting displays.

5-16

Campus-REX RS Interface Card User Manual