Power Fail Recovery

The Power Fail Recovery feature allows the cycle status to be saved in memory in the event of a power failure.

If a cycle is in progress when the power fails, the cycle status is saved in memory. When power recovers, the control will determine whether to automatically continue the cycle from the point it left off, requiring the user to press the START pad to continue the cycle, or end the cycle and put the control into the Ready Mode.

Power Fail Reset Disabled

If the European Community (EC) Power Fail feature is disabled, the control will automatically resume the cycle from the point it left off. Whenever the EC Power Fail feature is enabled and the power failure lasted more than two (2) seconds, the control will go back to the Start Mode and will prompt the user to press the START pad to continue the cycle from the point it left off.

Power Fail Reset Enabled

If the length of the power failure is less than the programmed Power Failure Reset time, the control will resume the cycle from the point it left off. The cycle will resume automatically unless the EC Power Fail feature is enabled and the failure lasted more than two (2) seconds which requires the user to press the START pad.

If the power failure lasted more than the programmed power failure reset time, the contol will end the cycle and will return to the Ready Mode. If, however, the cylinder is filled with water when the power recovers, the control will not go directly to Ready Mode, but will spin out the water first. In this case the control will enter the Start Mode at the Rinse Spin #1 step of the DELICATE Cycle prompting the user to press the START pad. Once the START pad is pressed, the control will start the Rinse Spin #1 step, then the Final Spin step and then end the cycle.

210140

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

127