Programming NetMaster
How to Read Table 4
Use this table to set the amount of time for Power Fail Reset.
The table range begins at 0 and ends at 255. Numbers entered between 0 and 127 turn the option OFF. If a number in this range is entered, the current cycle status will be saved for up to six years. When power is restored, the cycle will begin where it was interrupted.
If 133 is entered, the current cycle will be saved for up to five minutes. If power is not restored within five minutes, the control will erase the cycle status. The minimum power failure time is five minutes. The maximum power fail reset time is 127 minutes.
| “+025” |
|
|
NUMBER TO ENTER IN STEP 6 | POWER FAIL RESET TIME |
|
|
000 – 127 | Turned OFF |
| Cycle will be saved for a minimum of 6 years |
|
|
133 | 5 minutes without power before cycle is lost |
|
|
. . . add one minute for every number up to | |
|
|
255 | 127 minutes without power before cycle is lost |
|
|
| Table 4 |