Removing and replacing disk drives
Verifying that the system recognizes the new boot disk drive
To verify that the system recognizes the new boot disk drive:
1.Enter: format
A message similar to the following is displayed:
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0.c0t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107> /sbus@X,0/SUNW,socal@d,10000/sf@0,0/ssd@w<WWN>,0
Specify disk (enter its number):
The message displays the boot disk drive.
2.Enter: 0
3.Enter: q
4.Continue with Checking the status of the boot disk drive on page 38.
Checking the status of the boot disk drive
To check the status of the boot disk drive:
1.Enter:
. /opt/informix/bin/setenv
2.Enter:
onstat -d egrep "On-Line"
A message similar to the following is displayed. If the boot disk is not
Informix | Dynamic Server Version 9.40.UC1 | |
00:03:46 |
| |
|
|
|
3.Continue with Checking the status of the tape drives on page 39.
38 Avaya CMS R12 Sun Enterprise 3500 Computer CMS Upgrade Express