92 | Section 8: Setting Up - UNIX | AXIS 5400 User’s Manual |
|
|
|
String Substitutions The string substitution function performs search and replace operations on the print data. The primary application is to replace printer control commands. Up to twenty string substitutions may be specified individually for each logical printer.
All strings must be entered as hexadecimal byte values, and each match and substitute string must be preceded by a count byte.
You substitute command strings by editing the String Substitutions (PRx_STR) parameter.
Example: Assume that you want to replace the UNIX New Line (hex 0A) with an ASCII NewLine (hex 0D 0A) for logical printer PR1.
Follow the instructions below to substitute command strings:
1.Select the Printer1 Web page.
2.Enter the string 01 0A 02 0D 0A in the String Substitutions text field.
Hex Code |
| Explanation |
01 |
| length of the string you want to replace |
|
|
|
0A |
| the string you want to replace |
|
|
|
02 |
| length of the substitute string |
|
|
|
0D 0A |
| the substitute string |
|
|
|
UNIX
3.Click the Submit Printer1 settings button.
This is the default setting for logical printers PR5 through PR8.