138 | Appendix A: Test Button | AXIS 5400 User’s Manual |
|
|
|
OS/2 Windows NetWare
UNIX Macintosh
Factory Default Follow the instructions below to reset the AXIS 5400 to the factory Settings default settings:
1.Remove the external power supply to switch off the AXIS 5400.
2.Press and hold down the test button, while you plug the external power supply back in. Continue to hold down the test button, until the network indicator begins to flash at one second intervals. This should take at least 5 seconds.
3.Release the test button and wait until the network indicator flashes at least five times.
4.Press and hold the test button again until the network indicator remains constantly lit.
5.Restart the AXIS 5400 by disconnecting and reconnecting the external power supply.
The AXIS 5400 is now reset to factory default settings.
Note: ❏ All parameters except Node Address (NODE_ADDR), Internet Address (IP_ADDR) and DHCP enabled or disabled (DHCP_ENABLE.) are reset. If you want to change the these parameters, use either AXIS NetPilot or any standard Web browser. Please refer to Section 9 Management & Configuration, on page 97.