AXIS 5400 User’s Manual

Section 8: Setting Up - UNIX

93

 

 

 

Example: Assume that you want to replace the UNIX New Line (hex 0A) with an ASCII NewLine (hex 0D 0A), and the printer command ECG1 (hex 1B 47 31) with ECY (hex 1B 59) for logical printer PR2.

Follow the instructions below to substitute command strings:

1.Select the Printer2 Web page.

2.Enter the string 01 0A 02 0D 0A 03 1B 47 31 02 1B 59 in the String Substitutions text field.

Hex code

 

Explanation

01

 

length of the UNIX New Line command

 

 

 

0A

 

the UNIX New Line command

 

 

 

02

 

length of the ASCII New Line command

 

 

 

0D 0A

 

the ASCII New Line command

 

 

 

03

 

length of the replaced printer command

 

 

 

1B 47 31

 

the replaced printer command

 

 

 

02

 

length of the new printer command

 

 

 

1B 59

 

the new printer command

3.Click the Submit Printer2 settings button.

Note: Extensive use of string substitutions will naturally decrease the throughput rate of the AXIS 5400.