Baldor VS1MD instruction manual Parameter Read/Write

Models: VS1MD

1 168
Download 168 pages 41.14 Kb
Page 120
Image 120

The following table shows the fault type while this function is active.

No.

Display

Fault type

Diagnosis

 

 

 

 

1

UPHF

Switch above IGBT’s U phase fault

 

 

 

 

 

2

UPLF

Switch below IGBT’s U phase fault

 

 

 

 

 

3

vPHF

Switch above IGBT’s V phase fault

Contact sales representatives.

 

 

 

4

vPLF

Switch below IGBT’s V phase fault

 

 

 

 

 

5

WPHF

Switch above IGBT’s W phase fault

 

 

 

 

 

6

WPLF

Switch below IGBT’s U phase fault

 

 

 

 

 

7

UWSF

Output short between U and W

Check for a short in inverter output

 

 

 

8

vUSF

Output short between U and V

terminal, motor connection

terminal or the proper motor

 

 

 

 

 

 

connection.

9

WvSF

Output short between V and W

 

 

 

 

 

10

UPGF

Ground fault at U phase

 

 

 

 

Check for ground fault occurring at

 

 

 

11

vPGF

Ground fault at V phase

inverter output cable or motor or

 

 

 

motor insulation damage.

12

WPGF

Ground fault at W phase

 

 

 

 

 

13

UPOF

Output open at U phase

 

 

 

 

Check for proper connection of the

 

 

 

14

vPOF

Output open at V phase

motor to the inverter output or

 

 

 

proper motor connection.

15

WPOF

Output open at W phase

 

 

 

 

 

8.9Parameter Read/Write

Group

Display

Parameter Name

Setting

Range

Default

Unit

 

 

 

 

 

 

 

Function

H91

[Parameter Read]

1

0 to 1

0

 

 

 

 

 

 

 

group 2

H92

[Parameter Write]

1

0 to 1

0

 

 

 

 

 

 

 

 

 

 

Used to read/write Inverter Parameters using remote keypad.

!

8.9.1Parameter Read

ATTENTION:Take caution when Parameter write (H92) is executed. By doing this, parameters in inverter are cleared and parameters in remote keypad are copied to inverter.

 

Step 1. Move to H91 code.

 

Step 2.

Press Enter (

) key once. 0 will be displayed.

 

Step 3.

Press Up ( ) key once. Rd will be displayed.

 

Step 4.

Press Enter (

) key twice. Rd will be displayed

 

Step 5.

H91 is displayed￿￿when Parameter read is finished. VS1-MD AC Drive User Manual