H32 Slip Frequency

Range:

0-10 [Hz]

 

 

Default: 1.67

Access Configurable

See Also:

P33, H40

Enter the slip frequency in accordance with the following formula and motor nameplate.

f s = f r - (

r p m x

P

)

1 2 0

 

Where:

fs = Rated Slip Frequency fr = Rated Frequency rpm = Motor Nameplate rpm P = Number of Motor Poles

Example: Rated Freq: 60 Hz; Rated RPM: 1740 rpm; Poles: 4 fs = 60 - ((1740 x 4) / 120) = 2 HZ

H34 No Load Motor Current

Range:

0.1-20 [A]

 

 

Default: Based on drive rating

Access Configurable

Enter the current value detected when the motor is rotating at rated speed (remove any load connected to the motor shaft). For applications where it is difficult to measure the no load current, enter a value of 50% of the rated nameplate motor current in this parameter.

H36 Motor Efficiency

Range:

50-100 [%]

 

 

Default: 87

Access Configurable

Enter the motor efficiency from the motor nameplate.

Parameter Descriptions