Step 6.

Press Enter ( ) key. UL will be displayed.

 

 

 

 

 

 

 

Step 7. Parameter value can be changed in UL (Unlock) status. While UL is

 

 

 

displayed, press Enter ( ) key. H95 will be displayed.

 

 

 

8.11 Multi-function Output Terminal (MO) and Relay (3AC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group

 

Code

 

Parameter

 

 

Setting range

 

 

Initial

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I/O

 

t32

[Multi-function output

0

FDT-1

 

 

 

 

 

 

12

 

group

 

 

terminal Selection]

 

 

 

 

 

 

 

 

 

 

 

 

1

FDT-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t33

[Multi-function relay

2

FDT-3

 

 

 

 

 

 

17

 

 

 

 

Selection]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

FDT-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿

 

￿

4

FDT-5

 

 

 

 

 

 

 

 

 

 

 

 

5

Overload [OL ]

 

 

 

 

 

 

 

 

 

6

Inverter Overload [IOL ]

 

 

 

 

 

 

 

7

Motor stall [STALL]

 

 

 

 

 

 

 

 

8

Over voltage trip [OV]

 

 

 

 

 

 

 

 

9

Low voltage trip [LV]

 

 

 

 

 

 

 

 

10

Inverter overheat [OH]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Command loss

 

 

 

 

 

 

 

 

 

 

 

12

During run

 

 

 

 

 

 

 

 

 

 

 

 

13

During stop

 

 

 

 

 

 

 

 

 

 

 

 

14

During constant run

 

 

 

 

 

 

 

 

 

 

15

During speed searching

 

 

 

 

 

 

 

 

 

16

Wait time for run signal input

 

 

 

 

 

 

 

 

17

Fault output

 

 

 

 

 

 

 

 

 

 

 

 

18

Cooling fan trip alarm

 

 

 

 

 

 

t34

[Fault relay output]

 

When

 

 

When trip

When

 

 

 

 

 

 

 

 

 

setting

 

 

other

 

low

 

 

 

 

 

 

 

 

 

H26

 

 

than low

 

voltage

 

 

 

 

 

 

 

 

 

[Number

 

voltage

 

trip

 

 

 

 

 

 

 

 

 

of auto

 

 

trip

 

 

occurs

 

 

 

 

 

 

 

 

 

restart

 

 

occurs￿

￿

 

 

 

 

 

 

 

 

 

 

tries]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 2

 

 

Bit 1

 

Bit 0

 

 

 

 

 

 

 

 

0

-

 

 

 

-

 

-

2

 

 

 

 

 

 

 

1

-

 

 

 

-

 

 

 

 

 

 

 

 

 

 

2

-

 

 

 

 

 

￿-

 

 

 

 

 

 

 

 

3

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

-

 

-

 

 

 

 

 

 

 

 

5

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

7

and relay￿

 

 

 

 

 

 

 

 

Select the desired

item to be output via MO

terminal

(30AC).

 

 

 

 

t34: When 17 [Fault display] is selected in t32 and t33, Multi-function output terminal

and relay will be activated with the value in t34.

 

 

 

￿

 

 

 

Customizing for Your Application

 

 

 

 

 

 

 

 

 

 

 

 

8-21

Page 123
Image 123
Baldor VS1MD instruction manual Multi-function Output Terminal MO and Relay 3AC, FDT-4 FDT-5

VS1MD specifications

The Baldor VS1MD is a state-of-the-art variable speed drive designed for demanding applications requiring seamless control of induction motors. This drive exemplifies Baldor’s commitment to providing efficient and reliable solutions for industrial automation. Balancing user-friendliness with advanced engineering, the VS1MD addresses the needs of both new installations and retrofitting existing systems.

One of the most notable features of the VS1MD is its compact design. Engineered to save space without compromising performance, this drive can fit into tight installations, making it an ideal choice for crowded panels or machinery. The drive is available in a range of power ratings, accommodating various motor sizes and operational requirements.

The VS1MD incorporates advanced digital signal processing technology, ensuring precise control of motor speed and torque. The adaptive control algorithm optimizes performance across varying load conditions, resulting in smoother operation and improved energy efficiency. This technology not only enhances performance but also enhances the drive’s lifespan by minimizing stress on the motor and related components.

User interface is another strong point of the VS1MD. The drive features a clear display and intuitive controls, allowing for easy setup and troubleshooting. Operators can easily navigate through various parameters, ensuring quick adjustments and fine-tuning to meet specific performance needs.

For enhanced connectivity, the VS1MD includes multiple communication options such as Modbus RTU and CANopen protocols. This flexibility enables integration into existing networks and facilitates communication with other automation devices. The drive can also be seamlessly connected to centralized control systems, allowing for comprehensive monitoring and management.

Safety features are paramount in ensuring reliable operation in industrial environments. The Baldor VS1MD includes built-in protection mechanisms against common issues such as overvoltage, overcurrent, and overheating. These safety measures safeguard both the drive and the motor, reducing the likelihood of costly downtime and repair.

Furthermore, the VS1MD is designed with energy efficiency in mind. It can contribute to significant energy savings, reducing operational costs while promoting a greener approach to industrial processes. This drive effectively meets the requirements of industries that prioritize sustainability alongside performance.

In conclusion, the Baldor VS1MD is a versatile and powerful variable speed drive that stands out due to its compact design, advanced control technologies, user-friendly interface, robust safety features, and energy-saving capabilities. It is an exemplary choice for industries looking to enhance their automation processes with reliable and efficient motor control solutions. Whether applied in manufacturing, HVAC, or other sectors, the VS1MD proves to be a valuable asset for optimizing operational performance.