Baldor VS1MD instruction manual Sets the minimum voltage of the Analog Input V1 input

Models: VS1MD

1 168
Download 168 pages 41.14 Kb
Page 66
Image 66

t37

Frequency corresponding to t36

 

Range:

0 - 400 [Hz]

 

Default:

0

 

Access

Tunable

 

See Also:

t37

 

Sets the inverter output minimum frequency at minimum voltage of the NV

 

input.

 

 

 

 

 

t38

Analog Input 0 to -10V (NV) Max voltage

 

 

 

 

Range:

0 - 10V

 

Default:

10

 

Access

Tunable

 

See Also:

P40, t39

 

Sets the maximum voltage of the NV input.

 

 

 

 

t39

Frequency corresponding to t38

 

 

 

 

Range:

0 - 400 [Hz]

 

Default:

60

 

Access

Tunable

 

See Also:

t38

 

Sets the inverter output maximum frequency at maximum voltage of the NV

 

input.

 

 

 

 

 

t40

Analog Input 0 - 10V (V1) Filter time constant

 

 

 

 

Range:

0 - 9999

 

Default:

10

 

Access

Tunable

 

See Also:

P40, t41-t43

 

Adjusts the responsiveness of the Analog (V1) input (0~+10V) to filter noise.

 

 

 

 

t41

Analog Input 0 - 10V (V1) Min voltage

 

 

 

 

Range:

0 - 10V

 

Default:

0

 

Access

Tunable

 

See Also:

t40, t42

 

 

 

Sets the minimum voltage of the Analog Input (V1) input.

7-22

VS1MD AC Drive User Manual

Page 66
Image 66