WARNING: Do not remove cover for at least five (5) minutes after AC power is disconnected

!to allow capacitors to discharge. Dangerous voltages are present inside the equipment. Electrical shock can cause serious or fatal injury.

WARNING: Improper operation of control may cause violent motion of the motor shaft and driven

!equipment. Be certain that unexpected motor shaft movement will not cause injury to personnel or damage to equipment. Certain failure modes of the control can produce peak torque of several times the rated motor torque.

WARNING: Motor circuit may have high voltage present whenever AC power is applied, even

!when motor is not rotating. Electrical shock can cause serious or fatal injury.

WARNING: Dynamic brake resistors may generate enough heat to ignite combustible materials.

!Keep all combustible materials and flammable vapors away from brake resistors.

WARNING: The motor shaft will rotate during the touting procedure. Be certain that unexpected

!motor shaft movement will not cause injury to personnel or damage to equipment.

CAUTION: Disconnect motor leads (U, V & W) from control before you perform a “Megger” test

!on the motor. Failure to disconnect motor from the control will result in extensive damage to the control. The control is tested at the factory for high voltage / leakage resistance as part of Underwriter Laboratory requirements.

CAUTION: Suitable for use on a circuit capable of delivering not more than the RMS

!symmetrical short circuit amperes listed here at rated voltage.

Horsepower RMS Symmetrical Ampheres

1-305,000

CAUTION: Do not connect AC power to the Motor terminals U, V and W. Connecting AC power

!to these terminals may result in damage to the control.

CAUTION: Baldor recommends not to use "Grounded Leg Delta" transformer power leads that

!may create ground loops. Instead, we recommend using a four wire Wye.

CAUTION: Only Baldor cables should be used to connect the keypad and control. These are

!special cables to protect the control and keypad. Damage associated with other cable types are not covered by the Baldor warranty.

CAUTION: If an M-Contactor is installed, the control must be disabled for at least 200msec

!before the M-Contactor is opened. If the M-Contactor is opened while the control is supplying voltage and current to the motor, the control may be damaged. Before the control is enabled, the M-Contactor must be closed for at least 200msec.

CAUTION: Use of power correction capacitors on the output of the drive can result in erratic

!operation of the motor, nuisance tripping, and/or permanent damage to the drive. Remove power correction capacitors before proceeding. Failure to observe this precaution could result in damage to, or destruction of, the equipment.

-3

Page 3
Image 3
Baldor VS1MD instruction manual Horsepower RMS Symmetrical Ampheres

VS1MD specifications

The Baldor VS1MD is a state-of-the-art variable speed drive designed for demanding applications requiring seamless control of induction motors. This drive exemplifies Baldor’s commitment to providing efficient and reliable solutions for industrial automation. Balancing user-friendliness with advanced engineering, the VS1MD addresses the needs of both new installations and retrofitting existing systems.

One of the most notable features of the VS1MD is its compact design. Engineered to save space without compromising performance, this drive can fit into tight installations, making it an ideal choice for crowded panels or machinery. The drive is available in a range of power ratings, accommodating various motor sizes and operational requirements.

The VS1MD incorporates advanced digital signal processing technology, ensuring precise control of motor speed and torque. The adaptive control algorithm optimizes performance across varying load conditions, resulting in smoother operation and improved energy efficiency. This technology not only enhances performance but also enhances the drive’s lifespan by minimizing stress on the motor and related components.

User interface is another strong point of the VS1MD. The drive features a clear display and intuitive controls, allowing for easy setup and troubleshooting. Operators can easily navigate through various parameters, ensuring quick adjustments and fine-tuning to meet specific performance needs.

For enhanced connectivity, the VS1MD includes multiple communication options such as Modbus RTU and CANopen protocols. This flexibility enables integration into existing networks and facilitates communication with other automation devices. The drive can also be seamlessly connected to centralized control systems, allowing for comprehensive monitoring and management.

Safety features are paramount in ensuring reliable operation in industrial environments. The Baldor VS1MD includes built-in protection mechanisms against common issues such as overvoltage, overcurrent, and overheating. These safety measures safeguard both the drive and the motor, reducing the likelihood of costly downtime and repair.

Furthermore, the VS1MD is designed with energy efficiency in mind. It can contribute to significant energy savings, reducing operational costs while promoting a greener approach to industrial processes. This drive effectively meets the requirements of industries that prioritize sustainability alongside performance.

In conclusion, the Baldor VS1MD is a versatile and powerful variable speed drive that stands out due to its compact design, advanced control technologies, user-friendly interface, robust safety features, and energy-saving capabilities. It is an exemplary choice for industries looking to enhance their automation processes with reliable and efficient motor control solutions. Whether applied in manufacturing, HVAC, or other sectors, the VS1MD proves to be a valuable asset for optimizing operational performance.