Baldor VS1MD instruction manual Modifying the Value of a Parameter

Models: VS1MD

1 168
Download 168 pages 41.14 Kb
Page 40
Image 40

The following example shows how to use a previously stored Jump Code.

Table 6.7 – Using a Previously Stored Jump Code

Procedure

Sample Display

Step 1. From the operation mode, press and hold down the ENTER key for at least two seconds to change the drive to the programming mode. The “PROG” LED will illuminate indicating that the drive is in programming mode. The drive will display the first parameter of the “Display” group.

Step 2. Press the right arrow to change to the “Parameters” group.

Step 3. Press the ENTER key to access the Jump Code.

Step 4. Press the ENTER key a second time and the desired parameter will be displayed.

6.8Modifying the Value of a Parameter

The parameters located in the Display group are read-only and can not be modified. All other parameters (with a few exceptions) can be modified by the user. Some parameters are configurable - meaning that the drive must be stopped before the parameter can be modified, while others are tunable - meaning that the parameter can be modified while the drive is stopped or running.

6-8

VS1MD AC Drive User Manual

Page 40
Image 40
Baldor VS1MD instruction manual Modifying the Value of a Parameter