The following example shows how to modify the acceleration time located in parameter P41.

Table 6.8 – Modifying Parameter Values

Program Group

Step 1. From the operation mode, press and hold down the ENTER key for at least two seconds to change the drive to the programming mode. The “PROG” LED will illuminate indicating that the drive is in programming mode. The drive will display the first parameter of the “Display” group.

Step 2. Press the right arrow key to change to the “Parameters” group.

Step 3. Use the up arrow or the jump code to display the acceleration time parameter P41.

Step 4. Momentarily press the ENTER key to begin the parameter value edit mode. Notice that the tenths digit is highlighted for editing. At this point you can use the up arrow key to increment the value all the way to the new setting (16.0 in this example) or proceed with the following steps.

Step 5. Press the left arrow key to select the ones digit for editing.

Step 6. Press the up arrow key to increment the ones digit from a 5 to a 6.

Step 7. Press the left arrow key to select the tens digit for editing.

Step 8. Press the up arrow key to increment the tens digit from a 0 to a 1.

Using the Keypad