Example 2)

 

 

H 76 =

T _ dec

100[%]

 

 

T _ dec + T _ steady1

+ T _ acc + T _ steady2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

 

 

 

 

￿￿￿￿￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H77

Cooling Fan Control

￿￿￿￿￿￿￿￿￿

 

 

￿￿￿￿￿￿￿￿￿

 

Range:

0 - 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default:

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Access

Configurable

 

 

 

 

 

 

 

 

 

This parameter determines if the cooling fan for the drive will always

 

operate or only run when the temperature of the inverter exceeds the

 

protective temperature limit.

 

 

 

 

 

 

 

 

 

0 = Always ON, cooling fan operates when power is applied to drive. Fan

 

turns off when inverter voltage becomes low due to power off.

 

1 = Fan operates when temp above limit; fan begins to operate when power

 

is ON and a operating command is ON. Fan turns off when operating

 

command is turned off. Fan will continue to operate if the heat sink

 

temperature exceeds a certain limit regardless of operating command. Use

 

this￿￿￿￿￿setting for applications requiring frequent starts and stops.

H78

Operating method when cooling fan fails

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range:

0 - 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default:

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Access

Configurable

 

 

 

 

 

 

 

 

 

See Also:

t32, t33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This parameter determines if what the drive will do if the cooling fan fails.

0 = Continuous operation when cooling fan malfunctions

Setting t32 or t33 = 18 (Cooling Fan Fault Alarm) will send an alarm signal to the output.

ATTENTION: If operation is continued after a fan trip occurs, an overheat trip may happen and protective functions may be activated. It may also reduce the life of main board components due to a rise in inverter internal temperatures.

Parameter Descriptions

7-55

Page 99
Image 99
Baldor VS1MD instruction manual Dec, H77 Cooling Fan Control Range Default Access

VS1MD specifications

The Baldor VS1MD is a state-of-the-art variable speed drive designed for demanding applications requiring seamless control of induction motors. This drive exemplifies Baldor’s commitment to providing efficient and reliable solutions for industrial automation. Balancing user-friendliness with advanced engineering, the VS1MD addresses the needs of both new installations and retrofitting existing systems.

One of the most notable features of the VS1MD is its compact design. Engineered to save space without compromising performance, this drive can fit into tight installations, making it an ideal choice for crowded panels or machinery. The drive is available in a range of power ratings, accommodating various motor sizes and operational requirements.

The VS1MD incorporates advanced digital signal processing technology, ensuring precise control of motor speed and torque. The adaptive control algorithm optimizes performance across varying load conditions, resulting in smoother operation and improved energy efficiency. This technology not only enhances performance but also enhances the drive’s lifespan by minimizing stress on the motor and related components.

User interface is another strong point of the VS1MD. The drive features a clear display and intuitive controls, allowing for easy setup and troubleshooting. Operators can easily navigate through various parameters, ensuring quick adjustments and fine-tuning to meet specific performance needs.

For enhanced connectivity, the VS1MD includes multiple communication options such as Modbus RTU and CANopen protocols. This flexibility enables integration into existing networks and facilitates communication with other automation devices. The drive can also be seamlessly connected to centralized control systems, allowing for comprehensive monitoring and management.

Safety features are paramount in ensuring reliable operation in industrial environments. The Baldor VS1MD includes built-in protection mechanisms against common issues such as overvoltage, overcurrent, and overheating. These safety measures safeguard both the drive and the motor, reducing the likelihood of costly downtime and repair.

Furthermore, the VS1MD is designed with energy efficiency in mind. It can contribute to significant energy savings, reducing operational costs while promoting a greener approach to industrial processes. This drive effectively meets the requirements of industries that prioritize sustainability alongside performance.

In conclusion, the Baldor VS1MD is a versatile and powerful variable speed drive that stands out due to its compact design, advanced control technologies, user-friendly interface, robust safety features, and energy-saving capabilities. It is an exemplary choice for industries looking to enhance their automation processes with reliable and efficient motor control solutions. Whether applied in manufacturing, HVAC, or other sectors, the VS1MD proves to be a valuable asset for optimizing operational performance.