Baldor VS1MD Function Group 2 Parameters, H0 Jump Code Range 0 Default Access Tunable

Models: VS1MD

1 168
Download 168 pages 41.14 Kb
Page 84
Image 84

7.6Function Group 2 Parameters

H0 Jump Code

Range: 0 - 95

Default: 0

Access Tunable

Sets the code to jump directly to a specific parameter within the group.

H1

Last Fault 1

 

H2

Last Fault 2

 

H3

Last Fault 3

 

H4

Last Fault 4

 

H5

Last Fault 5

 

 

 

 

 

Range:

n/a

 

Default:

0

 

Access

Read Only

 

See also:

H6

 

Stores information on the types of faults, the frequency, the current and the

 

Accel/Decel condition at the time of fault. The latest fault is automatically

 

stored in the H1 – Fault History 1. Up to the last five faults can be stored.

 

When a fault occurs during operation, it can be monitored in the d – display

 

parameters under nOn. See Chapter 9 – Troubleshooting for information on

 

fault codes and actions.

 

 

 

 

H6

Reset Fault History

 

 

 

 

Range:

0 - 1

 

Default:

0

 

Access

Tunable

 

See also:

H1-H5

 

 

 

Clears the fault history saved in H1 to H5.

7-40