Baldor VS1MD Basic Program Group Parameters, P0 Jump Code Range30 Default AccessTunable

Models: VS1MD

1 168
Download 168 pages 41.14 Kb
Page 49
Image 49

7.3Basic Program Group Parameters

The Basic Program Group (P) contains the parameters most commonly used in start-up.

P0 Jump Code

Range:30 -47

Default: 30

AccessTunable

Sets the code to jump directly to a specific parameter within the group.

P30

Motor HP Select

 

 

 

Range:

0.5

= 0.5 HP

 

 

1

= 1 HP

 

 

2

= 2 HP

 

 

3

= 3 HP

 

 

5

= 5 HP

 

 

7.5

= 7.5 HP

 

 

10

= 10 HP

 

Default:

 

Preset based on drive rating.

 

Access

 

Configurable

 

See also:

 

P32 - P34

 

 

 

 

Sets the motor type connected to the drive output side.

P32 Motor Rated Current

Range:

0.5 - 50 Amps

Default: Preset based on drive rating

AccessConfigurable

See Also:

P30, P33, P34

Enter motor rated current on the nameplate.

P33

Pole Number

 

 

Range:

2, 4, 6, 8, 10, 12

 

Default:

4

 

Access

Configurable

 

See Also:

P30, P32, P34

 

 

 

Select number of motor poles

Parameter Descriptions

7-5

Page 49
Image 49
Baldor VS1MD Basic Program Group Parameters, P0 Jump Code Range30 Default AccessTunable, P30 Motor HP Select Range