Baldor VS1MD instruction manual Display Group Parameters

Models: VS1MD

1 168
Download 168 pages 41.14 Kb
Page 46
Image 46

7.2Display Group Parameters

Parameters in this group are display only and can be used to monitor drive conditions. To change the active display for the drive, use parameter H72 - Power On Display.

d0

Frequency Command

 

 

 

 

 

Range:

0.0 to Frequency High Limit (P36) [Hz]

 

Default:

Read Only

 

 

 

 

Displays the value of the active frequency command. The commanded

 

frequency is displayed even if the drive is not running.

 

 

 

 

 

 

d1

Motor RPM

 

 

 

 

 

Range:

0.0 Motor RPM (based on P33 Motor

 

 

Poles) [RPM]

 

Default:

Read Only

 

 

 

 

Displays the output motor RPM. Motor RPM is scaled based on output

 

frequency present on terminals U, V and W based on the setting in P33

 

– Motor Poles.

 

 

 

 

 

 

 

d2

Output Current

 

 

 

 

 

Range:

0.0 to Motor Rated Current (P32) [Amps]

 

Default:

Read Only

 

 

 

 

Displays the value of the output current present at terminals U, V and W.

 

 

 

 

 

 

d3

Output Voltage

 

 

 

 

 

Range:

0.0 to Drive Rated Voltage [volts]

 

Default:

Read Only

 

 

 

 

Displays output voltage present at U, V, W.

 

 

 

 

 

 

d4

Output Power

 

 

 

 

 

Range:

0.0 to (Drive Rated Power x 2) [kW]

 

Default:

Read Only

 

 

 

 

Displays the value of the output power present at terminals U, V and W.

7-2

VS1MD AC Drive User Manual

Page 46
Image 46
Baldor VS1MD instruction manual Display Group Parameters